Initial Operating Room Experience with Digital Variance Angiography in Carbon Dioxide-Assisted Lower Limb Interventions: A Pilot Study.


ABSTRACT: PURPOSE:In retrospective clinical studies digital variance angiography (DVA) provided higher contrast-to-noise ratio and better image quality than digital subtraction angiography (DSA). Our aim was to verify the clinical usefulness and benefits of DVA in carbon dioxide (CO2)-assisted lower limb interventions. MATERIALS AND METHODS:A workstation running the DVA software was integrated into a Siemens Artis Zee with Pure angiography system, and this new image processing technology was used in four patients (3 male, 1 female, age: 76.2?±?4.2 years) with peripheral artery disease (PAD, Rutherford 2-3) and impaired renal function (average eGFR 25.5?±?11.2 ml/min/1.73 m2). The DSA and DVA images of 46 CO2-assisted runs were visually evaluated by five experts in single-image evaluation using a 5-grade Likert scale and in paired comparisons. RESULTS:DVA images received significantly higher score (3.84?±?0.10) than DSA images (3.31?±?0.10, p?

SUBMITTER: Gyano M 

PROVIDER: S-EPMC7369257 | biostudies-literature | 2020 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Initial Operating Room Experience with Digital Variance Angiography in Carbon Dioxide-Assisted Lower Limb Interventions: A Pilot Study.

Gyánó Marcell M   Csobay-Novák Csaba C   Berczeli Márton M   Góg István I   Kiss János P JP   Szigeti Krisztián K   Osváth Szabolcs S   Nemes Balázs B  

Cardiovascular and interventional radiology 20200531 8


<h4>Purpose</h4>In retrospective clinical studies digital variance angiography (DVA) provided higher contrast-to-noise ratio and better image quality than digital subtraction angiography (DSA). Our aim was to verify the clinical usefulness and benefits of DVA in carbon dioxide (CO<sub>2</sub>)-assisted lower limb interventions.<h4>Materials and methods</h4>A workstation running the DVA software was integrated into a Siemens Artis Zee with Pure angiography system, and this new image processing te  ...[more]

Similar Datasets

| S-EPMC10219428 | biostudies-literature
| S-EPMC8575921 | biostudies-literature
| S-EPMC7683322 | biostudies-literature
| S-EPMC10384110 | biostudies-literature
| PRJEB11484 | ENA
| S-EPMC6180416 | biostudies-literature
| S-EPMC6642078 | biostudies-literature
| S-EPMC7012309 | biostudies-literature
| S-EPMC10582520 | biostudies-literature
2020-10-22 | GSE159610 | GEO