Unknown

Dataset Information

0

Practical Protocol for Making Calibration Curves for Direct and Sensitive Quantitative LC Orbitrap-MS of Large Neuropeptides.


ABSTRACT: Peptides larger than 3-4?kDa, such as neuropeptide Y (NPY), orexin-B, and alpha-MSH, have practical issues that arise when conducting direct and sensitive quantitative liquid chromatography (LC) orbitrap-FT mass spectrometry (MS) due to their adsorption and low ionization efficiency, especially in standard solutions. A mixing solvent consisting of 0.5% trifluoroacetic acid (TFA) and 35-50% aq. acetonitrile was developed as the standard NPY for creating calibration curves, as well as a matrix to block the experimental tube surface to minimize adsorption. The mixture matrix effectively blocked non-specific adsorption of the standard peptides with tryptic digested bovine serum albumin (BSA) (small fragment peptides) and orexin-B (a large chain peptide). A sample containing 1?:?100 peptide:water was detected in the developed sample solution. Finally, 2 to 1,000?fmol/?L NPY could be analyzed quantitatively and reproducibly using conventional LC-MS. Parameters of the calibration curves, such as X-intercept, Bias (%), and relative standard deviation (RSD), were adjusted to optimize the sample solutions and the sensitive and quantitative LC-MS analyses.

SUBMITTER: Yamagaki T 

PROVIDER: S-EPMC7392841 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Practical Protocol for Making Calibration Curves for Direct and Sensitive Quantitative LC Orbitrap-MS of Large Neuropeptides.

Yamagaki Tohru T   Yamazaki Takashi T  

Mass spectrometry (Tokyo, Japan) 20200803 1


Peptides larger than 3-4 kDa, such as neuropeptide Y (NPY), orexin-B, and alpha-MSH, have practical issues that arise when conducting direct and sensitive quantitative liquid chromatography (LC) orbitrap-FT mass spectrometry (MS) due to their adsorption and low ionization efficiency, especially in standard solutions. A mixing solvent consisting of 0.5% trifluoroacetic acid (TFA) and 35-50% aq. acetonitrile was developed as the standard NPY for creating calibration curves, as well as a matrix to  ...[more]

Similar Datasets

| S-EPMC4439250 | biostudies-other
| S-EPMC6316396 | biostudies-literature
| S-EPMC8154743 | biostudies-literature
| S-EPMC2639432 | biostudies-literature
| S-EPMC6077116 | biostudies-literature
| S-EPMC5703036 | biostudies-literature
| S-EPMC5696090 | biostudies-literature
| S-EPMC5118035 | biostudies-literature
| S-EPMC8125850 | biostudies-literature
| S-EPMC7545581 | biostudies-literature