Unknown

Dataset Information

0

Adverse events associated with prophylactic corticosteroid use before extubation: a cohort study.


ABSTRACT: Background:Systemic corticosteroid use is recommended before extubation in mechanically ventilated patients to prevent postextubation airway complications and reintubation. However, the adverse events associated with such use remain unclear. This study aimed to describe the incidence of adverse events associated with prophylactic corticosteroid use before extubation in mechanically ventilated adult patients. Methods:This is a retrospective cohort study of 251 mechanically ventilated adults who received prophylactic corticosteroids in the intensive care units of four tertiary-care hospitals. The patients received 20 mg methylprednisolone at 12, 8, 4, and 0 hours before extubation (total dose, 80 mg) and were followed for 72 hours after extubation. The primary outcome was a clinically significant increase in blood glucose levels of ?100 mg/dL within 24 and 72 hours after prophylactic corticosteroid administration. Results:Fifty-seven (23.1%) out of 247 patients and 73 (30.3%) out of 241 patients showed a clinically significant increase in blood glucose levels within 24 and 72 hours after receiving prophylactic corticosteroids, respectively. The clinically significant increase in blood glucose levels was significantly associated with underlying diabetes mellitus and was not significantly associated with hyperglycemia within 3 days before the initiation of prophylactic corticosteroids or with patient age. New-onset infections and delirium were also common, with incidences of 7.6% and 7.7%, respectively. Conclusions:Prophylactic corticosteroid use before extubation was associated with adverse events, the most common of which was increased blood glucose levels. Lower doses of prophylactic corticosteroids may need to be considered in patients with diabetes mellitus or hyperglycemia.

SUBMITTER: Kuriyama A 

PROVIDER: S-EPMC7396740 | biostudies-literature | 2020 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

Adverse events associated with prophylactic corticosteroid use before extubation: a cohort study.

Kuriyama Akira A   Egawa Satoshi S   Kataoka Jun J   Sakuraya Masaaki M   Matsumura Masami M  

Annals of translational medicine 20200701 14


<h4>Background</h4>Systemic corticosteroid use is recommended before extubation in mechanically ventilated patients to prevent postextubation airway complications and reintubation. However, the adverse events associated with such use remain unclear. This study aimed to describe the incidence of adverse events associated with prophylactic corticosteroid use before extubation in mechanically ventilated adult patients.<h4>Methods</h4>This is a retrospective cohort study of 251 mechanically ventilat  ...[more]

Similar Datasets

| S-EPMC7900536 | biostudies-literature
| S-EPMC9772659 | biostudies-literature
| S-EPMC6520321 | biostudies-literature
| S-EPMC6934562 | biostudies-literature
| S-EPMC8100661 | biostudies-literature
| S-EPMC7935747 | biostudies-literature
| S-EPMC7011365 | biostudies-literature
| S-EPMC8056312 | biostudies-literature
| S-EPMC9303779 | biostudies-literature
| S-EPMC10288443 | biostudies-literature