Microbial Cross-contamination in Multidose Eyedrops: The Impact of Instillation Angle and Bottle Geometry.


ABSTRACT: Purpose:To evaluate the impact of instillation angle and nozzle tip geometry on cross-contamination risk of multidose ocular solution bottles. Methods:Pseudomonas aeruginosa solution was passed exclusively on the outside of the nozzle to simulate contamination on the exterior of topical agents. Three drops were administered from angles of 90° and 45° from bottles with either a round or sharp tip geometry, and the cultures were examined for growth. Two-hundred sixteen cultures from nine lubricant eyedrop brands currently existing in the Brazilian market were assessed for bacterial growth. Results:After seven days, bacterial contamination was detected in 53.7% of cultures when drops were administered at 90° and in 70.4% of cultures at 45°. Eyedrops collected from a rounded nozzle tip and an instillation angle of 90° transmitted bacteria in 69.4% of cases, whereas those administered from a sharp tip transmitted bacteria in only 22.2% of cases (P = 0.001). At an instillation angle of 45°, contamination was identified in 83.3% of bottles with a rounded tip geometry and in only eight of 18 bottles (44.4%) from those with a sharp nozzle geometry (P = 0.005). Conclusions:Adjusting the instillation angle of eyedrop solutions to 90°, as well as using a nozzle geometry that prevents flow of the solution to the side of the bottle, significantly reduced contamination rates. Translational Relevance:Standardizing drop bottles and adjusting delivery angle shows promise in reducing contamination rates and may critically impact the quality of care for patients requiring topical therapeutic agents.

SUBMITTER: da Costa AX 

PROVIDER: S-EPMC7414607 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Microbial Cross-contamination in Multidose Eyedrops: The Impact of Instillation Angle and Bottle Geometry.

da Costa Alexandre Xavier AX   Yu Maria Cecilia Zorat MCZ   de Freitas Denise D   Cristovam Priscila Cardoso PC   LaMonica Lauren C LC   Dos Santos Vagner Rogerio VR   Gomes José Alvaro Pereira JAP  

Translational vision science & technology 20200605 7


<h4>Purpose</h4>To evaluate the impact of instillation angle and nozzle tip geometry on cross-contamination risk of multidose ocular solution bottles.<h4>Methods</h4><i>Pseudomonas aeruginosa</i> solution was passed exclusively on the outside of the nozzle to simulate contamination on the exterior of topical agents. Three drops were administered from angles of 90° and 45° from bottles with either a round or sharp tip geometry, and the cultures were examined for growth. Two-hundred sixteen cultur  ...[more]

Similar Datasets

| S-EPMC8121298 | biostudies-literature
| S-EPMC3553749 | biostudies-literature
| S-EPMC8149423 | biostudies-literature
| S-EPMC8190654 | biostudies-literature
| S-EPMC8071874 | biostudies-literature
| S-EPMC6563523 | biostudies-literature
2021-11-08 | GSE186658 | GEO
| S-EPMC5897750 | biostudies-literature
| S-EPMC5370491 | biostudies-literature
| S-EPMC6131813 | biostudies-other