Unknown

Dataset Information

0

Complications from percutaneous-left ventricular assist devices versus intra-aortic balloon pump in acute myocardial infarction-cardiogenic shock.


ABSTRACT: BACKGROUND:There are limited data on the complications with a percutaneous left ventricular assist device (pLVAD) vs. intra-aortic balloon pump (IABP) in acute myocardial infarction-cardiogenic shock (AMI-CS). OBJECTIVE:To assess the trends, rates and predictors of complications. METHODS:Using a 17-year AMI-CS population from the National Inpatient Sample, AMI-CS admissions receiving pLVAD and IABP support were evaluated for vascular, lower limb amputation, hematologic, neurologic and acute kidney injury (AKI) complications. In-hospital mortality, hospitalization costs and length of stay in pLVAD and IABP cohorts with complications was studied. RESULTS:Of 168,645 admissions, 7,855 (4.7%) receiving pLVAD support. The pLVAD cohort had higher comorbidity, cardiac arrest (36.1% vs. 29.7%) and non-cardiac organ failure (74.7% vs. 56.9%) rates. Complications were higher in pLVAD compared to IABP cohort-overall 69.0% vs. 54.7%; vascular 3.8% vs. 2.1%; lower limb amputation 0.3% vs. 0.3%; hematologic 36.0% vs. 27.7%; neurologic 4.9% vs. 3.5% and AKI 55.4% vs. 39.1% (all p<0.001 except for amputation). Non-White race, higher comorbidity, organ failure, and extracorporeal membrane oxygen use were predictors of complications for both cohorts. The pLVAD cohort with complications had higher in-hospital mortality (45.5% vs. 33.1%; adjusted odds ratio 1.65 [95% confidence interval 1.55-1.75]), shorter duration of hospital stay, and higher hospitalization costs compared to the IABP cohort with complications (all p<0.001). These results were consistent in propensity-matched pairs. CONCLUSIONS:AMI-CS admissions receiving pLVAD had higher rates of complications compared to the IABP, with worse in-hospital outcomes in the cohort with complications.

SUBMITTER: Vallabhajosyula S 

PROVIDER: S-EPMC7444810 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>There are limited data on the complications with a percutaneous left ventricular assist device (pLVAD) vs. intra-aortic balloon pump (IABP) in acute myocardial infarction-cardiogenic shock (AMI-CS).<h4>Objective</h4>To assess the trends, rates and predictors of complications.<h4>Methods</h4>Using a 17-year AMI-CS population from the National Inpatient Sample, AMI-CS admissions receiving pLVAD and IABP support were evaluated for vascular, lower limb amputation, hematologic, neu  ...[more]

Similar Datasets

| S-EPMC7745888 | biostudies-literature
| S-EPMC7271960 | biostudies-literature
| S-EPMC5955398 | biostudies-literature
| S-EPMC8497228 | biostudies-literature
| S-EPMC8318473 | biostudies-literature
| S-EPMC7042879 | biostudies-literature
| S-EPMC6148415 | biostudies-literature
| S-EPMC8648392 | biostudies-literature
| S-EPMC5640487 | biostudies-literature
| S-EPMC7664793 | biostudies-literature