Quantification of steroid hormones in low volume plasma and tissue homogenates of fish using LC-MS/MS.


ABSTRACT: Quantification of steroid hormones in fish is an important step for toxicology and endocrinology studies. Among the hormone analysis techniques, liquid chromatography tandem mass spectrometry (LC-MS/MS) has widely been used for measuring hormones in various biological samples. Despite all improvements in the technique, detection of several hormones in a low volume of serum or plasma is still challenging. We developed a robust method for simultaneous quantification of 14 steroid hormones including corticosterone, cortisol, 11-ketotestosterone, progesterone, testosterone, 17OH-progesterone, aldosterone, dihydrotestosterone, estrone, 17β-estradiol, estriol, ethinylestradiol, levonorgestrel and equilin from volumes as low as 10 µL serum or plasma in a short run by LC-MS/MS. The lowest limit of detection in 10 µL serum was 0.012 ng/mL measured for cortisol, progesterone, testosterone, 17OH-progesterone and estrone. Use of high (25 times more) serum volume improved detection limit of hormones by 2-40 times. The method was compared with the radioimmunoassay technique in which testosterone and 17β-estradiol were highly correlated with R2 of 0.95 and 0.96, respectively. We validated the method by measuring four selected hormones, in low and high plasma volumes of largemouth bass (Micropterus salmoides). In addition, we developed a method to quantify hormones in whole body fish homogenates of small fish and compared the values to plasma concentrations, using fathead minnow (Pimephales promelas). Calculated concentrations of the hormones in plasma were consistent with those in the homogenate and 11-ketotestosterone and 17β-estradiol were significantly different in males and females. The ability to measure hormones from whole body homogenates was further evaluated in two model small fish species, zebrafish (Danio rerio) and juvenile silverside (Menidia beryllina). These results suggest that whole tissue homogenate is a reliable alternative for hormone quantification when sufficient plasma is not available.

SUBMITTER: Nouri MZ 

PROVIDER: S-EPMC7447131 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC8539474 | biostudies-literature
| S-EPMC9921923 | biostudies-literature
| S-EPMC11322771 | biostudies-literature
| S-EPMC4056446 | biostudies-literature
| S-EPMC4391816 | biostudies-literature
| S-EPMC6446716 | biostudies-literature
| S-EPMC8772585 | biostudies-literature
| S-EPMC4321809 | biostudies-literature
| S-EPMC7613747 | biostudies-literature
| S-EPMC4442878 | biostudies-literature