Unknown

Dataset Information

0

The effects of labor on airway outcomes with Supreme™ laryngeal mask in women undergoing cesarean delivery under general anesthesia: a cohort study.


ABSTRACT: BACKGROUND:Pregnancy is associated with higher incidence of failed endotracheal intubation and is exacerbated by labor. However, the influence of labor on airway outcomes with laryngeal mask airway (LMA) for cesarean delivery is unknown. METHODS:This is a secondary analysis of a prospective cohort study on LMA use during cesarean delivery. Healthy parturients who fasted >?4?h undergoing Category 2 or 3 cesarean delivery with Supreme™ LMA (sLMA) under general anesthesia were included. We excluded parturients with BMI >?35?kg/m2, gastroesophageal reflux disease, or potentially difficult airway (Mallampati score of 4, upper respiratory tract or neck pathology). Anesthesia and airway management reflected clinical standard at the study center. After rapid sequence induction and cricoid pressure, sLMA was inserted as per manufacturer's recommendations. Our primary outcome was time to effective ventilation (time from when sLMA was picked up until appearance of end-tidal carbon dioxide capnography), and secondary outcomes include first-attempt insertion failure, oxygen saturation, ventilation parameters, mucosal trauma, pulmonary aspiration, and Apgar scores. Differences between labor status were tested using Student's t-test, Mann-Whitney U test, or Fisher's exact test, as appropriate. Quantitative associations between labor status and outcomes were determined using univariate logistic regression analysis. RESULTS:Data from 584 parturients were analyzed, with 37.8% in labor. Labor did not significantly affect time to effective ventilation (mean (SD) for labor: 16.0 (5.75) seconds; no labor: 15.3 (3.35); mean difference: -0.65 (95%CI: -?1.49 to 0.18); p?=?0.1262). However, labor was associated with increased first-attempt insertion failure and blood on sLMA surface. No reduction in oxygen saturation or pulmonary aspiration was noted. CONCLUSIONS:Although no significant increase in time to effective ventilation was noted, labor may increase the number of insertion attempts and oropharyngeal trauma with sLMA use for cesarean delivery in parturients at low risk of difficult airway. Future studies should investigate the effects of labor on LMA use in high risk parturients. TRIAL REGISTRATION:The study was prospectively registered at clinicaltrials.gov ( NCT02026882 ) on 3 January 2014.

SUBMITTER: Lim MJ 

PROVIDER: S-EPMC7449044 | biostudies-literature | 2020 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

The effects of labor on airway outcomes with Supreme™ laryngeal mask in women undergoing cesarean delivery under general anesthesia: a cohort study.

Lim Ming Jian MJ   Tan Hon Sen HS   Tan Chin Wen CW   Li Shi Yang SY   Yao Wei Yu WY   Yuan Yong Jing YJ   Sultana Rehena R   Sng Ban Leong BL  

BMC anesthesiology 20200826 1


<h4>Background</h4>Pregnancy is associated with higher incidence of failed endotracheal intubation and is exacerbated by labor. However, the influence of labor on airway outcomes with laryngeal mask airway (LMA) for cesarean delivery is unknown.<h4>Methods</h4>This is a secondary analysis of a prospective cohort study on LMA use during cesarean delivery. Healthy parturients who fasted > 4 h undergoing Category 2 or 3 cesarean delivery with Supreme™ LMA (sLMA) under general anesthesia were includ  ...[more]

Similar Datasets

| S-EPMC6615162 | biostudies-literature
| S-EPMC5735892 | biostudies-literature
| S-EPMC6615212 | biostudies-literature
| S-EPMC6945475 | biostudies-literature
| S-EPMC5584514 | biostudies-literature
| S-EPMC4515321 | biostudies-literature
| S-EPMC5757964 | biostudies-literature
| S-EPMC8289652 | biostudies-literature
| S-EPMC6201529 | biostudies-literature
| S-EPMC4173459 | biostudies-other