An acidic-groups detection method and its application to analysis of Chinese humic acid samples.


ABSTRACT: The method of non-aqueous conductivity titration (NACT) of organic weak acids was applied to quickly and accurately determine the phenolic-hydroxyl and carboxyl-groups contents in humic acid. By varying the pH of the humic-acid sample, the concentration of the titrant, and the nitrogen-gas flow rate, the optimal titration conditions were determined to be a sample pH of 4, titrant concentration of 0.05 mol/L, and nitrogen-gas flow rate of 80 mL/min. Applying the detection method to p-hydroxybenzoic acid showed that its phenolic-hydroxyl content was 758.82±111.76 cmol/kg and carboxyl content was 744.44±51.11 cmol/kg. The theoretical phenolic-hydroxyl and carboxyl-groups contents of the p-hydroxybenzoic acid were 723.96 cmol/kg respectively, indicating that the method can accurately quantify the carboxyl and phenolic-hydroxyl groups in the sample. The NACT was used to measure the phenolic-hydroxyl and carboxyl-groups contents in humic acid quickly and accurately. In addition, 29 humic acid samples from 8 provinces of China covering the main humic-acid producing areas were collected and analyzed for acidic-groups content using the reported method.

SUBMITTER: Xu P 

PROVIDER: S-EPMC7449760 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

An acidic-groups detection method and its application to analysis of Chinese humic acid samples.

Xu Pengfei P   Wang Yuhao Y   Li Xue X   Chen Qingshuang Q   Hao Lujiang L   Zhang Jie J   Zhu Xiaoling X   Jia Baolei B  

PloS one 20200826 8


The method of non-aqueous conductivity titration (NACT) of organic weak acids was applied to quickly and accurately determine the phenolic-hydroxyl and carboxyl-groups contents in humic acid. By varying the pH of the humic-acid sample, the concentration of the titrant, and the nitrogen-gas flow rate, the optimal titration conditions were determined to be a sample pH of 4, titrant concentration of 0.05 mol/L, and nitrogen-gas flow rate of 80 mL/min. Applying the detection method to p-hydroxybenzo  ...[more]

Similar Datasets

| PRJNA953493 | ENA
| S-EPMC9077723 | biostudies-literature
| S-EPMC8158138 | biostudies-literature
| S-EPMC7806574 | biostudies-literature
2022-01-28 | E-MTAB-11280 | biostudies-arrayexpress
| S-EPMC4474753 | biostudies-literature
| S-EPMC9100522 | biostudies-literature
| S-EPMC2691089 | biostudies-literature
| S-EPMC5936920 | biostudies-literature
| S-EPMC11228040 | biostudies-literature