Unknown

Dataset Information

0

Head-to-Head Accuracy Comparison of Three Commercial COVID-19 IgM/IgG Serology Rapid Tests.


ABSTRACT: BACKGROUND:Comparative data of SARS-CoV-2 IgM/IgG serology rapid diagnostic tests (RDTs) is scarce. We thus performed a head-to-head comparison of three RDTs. METHODS:In this unmatched case-control study, blood samples from 41 RT-PCR-confirmed COVID-19 cases and 50 negative controls were studied. The diagnostic accuracy of three commercially available COVID-19 RDTs: NTBIO (RDT-A), Orient-Gene (RDT-B), and MEDsan (RDT-C), against both a recombinant spike-expressing immunofluorescence assay (rIFA) and Euroimmun IgG ELISA, was assessed. RDT results concordant with the reference methods, and between whole blood and plasma, were established by the Kendall coefficient. RESULTS:COVID-19 cases' median time from RT-PCR to serology was 22 days (interquartile range (IQR) 13-31 days). Whole-blood IgG detection with RDT-A, -B, and -C showed 0.93, 0.83, and 0.98 concordance with rIFA. Against rIFA, RDT-A sensitivity (SN) was 92% (95% CI: 78-98) and specificity (SP) 100% (95% CI: 91-100), RDT-B showed 87% SN (95% CI: 72-95) and 98% SP (95% CI: 88-100), and RDT-C 100% SN (95% CI: 88-100) and 98% SP (95% CI: 88-100). Against ELISA, SN and SP were above 90% for all three RDTs. CONCLUSIONS:RDT-A and RDT-C displayed IgG detection SN and SP above 90% in whole blood. These RDTs could be considered in the absence of routine diagnostic serology facilities.

SUBMITTER: Andrey DO 

PROVIDER: S-EPMC7463984 | biostudies-literature | 2020 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>Comparative data of SARS-CoV-2 IgM/IgG serology rapid diagnostic tests (RDTs) is scarce. We thus performed a head-to-head comparison of three RDTs.<h4>Methods</h4>In this unmatched case-control study, blood samples from 41 RT-PCR-confirmed COVID-19 cases and 50 negative controls were studied. The diagnostic accuracy of three commercially available COVID-19 RDTs: NTBIO (RDT-A), Orient-Gene (RDT-B), and MEDsan (RDT-C), against both a recombinant spike-expressing immunofluorescen  ...[more]

Similar Datasets

| S-EPMC7404380 | biostudies-literature
| S-EPMC7837473 | biostudies-literature
| S-EPMC6660329 | biostudies-literature
| S-EPMC7255746 | biostudies-literature
| S-EPMC6472756 | biostudies-literature
| S-EPMC8802144 | biostudies-literature
| S-EPMC4752287 | biostudies-literature
| S-EPMC7843253 | biostudies-literature
| S-EPMC2929071 | biostudies-literature
| S-EPMC7498027 | biostudies-literature