Repeatability, reproducibility, and comparison of ocular biometry using a new optical coherence tomography-based system and another device.


ABSTRACT: Precise measurement of axial length before cataract surgery is necessary for the proper lens implantation. We included 100 eyes of 56 patients in the study. The mean age was 41 (15-84 years). Measurements of axial length, anterior chamber depth (ACD) carried out with the new Revo NX were compared with those obtained with the IOLMaster 500. Interoperator testing was performed on 56 eyes of 56 participants. To test repeatability, axial length, ACD, central corneal thickness, and lens thickness were used. Inter-operator reproducibility was also assessed. The results were evaluated using Bland-Altman analyses. The mean ACD measured with the IOLMaster and Revo NX was 3.41 and 3.40 mm p?=?0.467, respectively. The interclass correlation was excellent at the level of 0.975. ICC for axial length values was 0.999, and the mean was equal to 23.47 for the new device and 23.48 for IOLMaster. ICC for Inter-operator repeatability was higher than 0.99 in all parameters. Revo NX showed a very high level of repeatability with ICC ranging from 0.9929 for central corneal thickness to 0.9997 for axial length. Both devices showed excellent agreement and differences that are insignificant, which suggests that they can be used interchangeably.

SUBMITTER: Wylegala A 

PROVIDER: S-EPMC7467923 | biostudies-literature | 2020 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Repeatability, reproducibility, and comparison of ocular biometry using a new optical coherence tomography-based system and another device.

Wylęgała Adam A   Bolek Bartłomiej B   Mazur Robert R   Wylęgała Edward E  

Scientific reports 20200902 1


Precise measurement of axial length before cataract surgery is necessary for the proper lens implantation. We included 100 eyes of 56 patients in the study. The mean age was 41 (15-84 years). Measurements of axial length, anterior chamber depth (ACD) carried out with the new Revo NX were compared with those obtained with the IOLMaster 500. Interoperator testing was performed on 56 eyes of 56 participants. To test repeatability, axial length, ACD, central corneal thickness, and lens thickness wer  ...[more]

Similar Datasets

| S-EPMC8590181 | biostudies-literature
| S-EPMC8897498 | biostudies-literature
| S-EPMC6193722 | biostudies-literature
| S-EPMC6859831 | biostudies-literature
| S-EPMC7585396 | biostudies-literature
| S-EPMC6062033 | biostudies-literature
| S-EPMC6906812 | biostudies-literature
| S-EPMC3535485 | biostudies-literature
| S-EPMC8284630 | biostudies-literature
| S-EPMC3505244 | biostudies-literature