Quantifying the effect of biopsy lateral decubitus patient positioning compared to supine prostate magnetic resonance image scanning on prostate translocation and distortion.


ABSTRACT: INTRODUCTION:More than a quarter of tumors are missed by magnetic resonance imaging/ultrasound (MRI/US) fusion-guided biopsy, the majority due to software-based misregistration. Transrectal approaches to biopsy are typically performed in the lateral decubitus position; conversely, diagnostic MRI is performed with the patient lying supine. Any position-related difference in prostate location or gland deformation could potentially exacerbate misregistration at subsequent biopsy. METHODS:Fifteen healthy male volunteers (mean age 35.9 years, range 27-53) were included in this prospective, institutional review board-approved study. Each volunteer had an MRI performed in the supine position, followed by the second in the lateral decubitus position (mimicking a typical biopsy position). MRI images were co-registered and analyzed in order to assess prostate translocation and distortion. RESULTS:Whole prostate translocation of ?5 mm was observed in 20% of patients and of ?3 mm in 60% of patients. When dividing the prostate into prostatic sectors, the prostatic base demonstrated the largest positional difference. When plotting the translocation directions with relative volume difference, there was a moderate negative correlation trend in the latero-lateral direction. Only minimal distortion was observed, with similar distortion among all prostatic sectors. CONCLUSIONS:Positional change affects the prostate translocation, however, the effect on prostate distortion appears to be negligible. Prostate translocation in latero-lateral direction can be minimized with larger bladder volumes. Prostate translocation needs to be considered alongside software misregistration error; however, positional change should not affect software registration of MRI/US fusion-guided prostate biopsy.

SUBMITTER: Snoj Z 

PROVIDER: S-EPMC7492036 | biostudies-literature | 2020 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantifying the effect of biopsy lateral decubitus patient positioning compared to supine prostate magnetic resonance image scanning on prostate translocation and distortion.

Snoj Žiga Ž   Rundo Leonardo L   Gill Andrew B AB   Barrett Tristan T  

Canadian Urological Association journal = Journal de l'Association des urologues du Canada 20200901 9


<h4>Introduction</h4>More than a quarter of tumors are missed by magnetic resonance imaging/ultrasound (MRI/US) fusion-guided biopsy, the majority due to software-based misregistration. Transrectal approaches to biopsy are typically performed in the lateral decubitus position; conversely, diagnostic MRI is performed with the patient lying supine. Any position-related difference in prostate location or gland deformation could potentially exacerbate misregistration at subsequent biopsy.<h4>Methods  ...[more]

Similar Datasets

| S-EPMC5629196 | biostudies-literature
| S-EPMC5124347 | biostudies-literature
| S-EPMC7807650 | biostudies-literature
| S-EPMC7966312 | biostudies-literature
| S-EPMC7087418 | biostudies-literature
| S-EPMC4680950 | biostudies-literature
| S-EPMC10244602 | biostudies-literature
| S-EPMC3431233 | biostudies-literature
| S-EPMC5429659 | biostudies-literature
| S-EPMC5439271 | biostudies-literature