Unknown

Dataset Information

0

Technical validity and usability of a novel smartphone-connected spirometry device for pediatric patients with asthma and cystic fibrosis.


ABSTRACT: BACKGROUND:Diagnosis and follow-up of respiratory diseases traditionally rely on pulmonary function tests (PFTs), which are currently performed in hospitals and require trained personnel. Smartphone-connected spirometers, like the Air Next spirometer, have been developed to aid in the home monitoring of patients with pulmonary disease. The aim of this study was to investigate the technical validity and usability of the Air Next spirometer in pediatric patients. METHODS:Device variability was tested with a calibrated syringe. About 90 subjects, aged 6 to 16, were included in a prospective cohort study. Fifty-eight subjects performed conventional spirometry and subsequent Air Next spirometry. The bias and the limits of agreement between the measurements were calculated. Furthermore, subjects used the device for 28 days at home and completed a subject-satisfaction questionnaire at the end of the study period. RESULTS:Interdevice variability was 2.8% and intradevice variability was 0.9%. The average difference between the Air Next and conventional spirometry was 40?mL for forced expiratory volume in 1 second (FEV1) and 3?mL for forced vital capacity (FVC). The limits of agreement were -270?mL and +352?mL for FEV1 and -403 mL and +397?mL for FVC. About 45% of FEV1 measurements and 41% of FVC measurements at home were acceptable and reproducible according to American Thoracic Society/European Respiratory Society criteria. Parents scored difficulty, usefulness, and reliability of the device 1.9, 3.5, and 3.8 out of 5, respectively. CONCLUSION:The Air Next device shows validity for the measurement of FEV1 and FVC in a pediatric patient population.

SUBMITTER: Kruizinga MD 

PROVIDER: S-EPMC7496177 | biostudies-literature | 2020 Jun

REPOSITORIES: biostudies-literature

altmetric image

Publications

Technical validity and usability of a novel smartphone-connected spirometry device for pediatric patients with asthma and cystic fibrosis.

Kruizinga Matthijs D MD   Essers Esmée E   Stuurman F E FE   Zhuparris Ahnjili A   van Eik Nellie N   Janssens Hettie M HM   Groothuis Iris I   Sprij Arwen J AJ   Nuijsink Marianne M   Cohen Adam F AF   Driessen Gertjan J A GJA  

Pediatric pulmonology 20200708 9


<h4>Background</h4>Diagnosis and follow-up of respiratory diseases traditionally rely on pulmonary function tests (PFTs), which are currently performed in hospitals and require trained personnel. Smartphone-connected spirometers, like the Air Next spirometer, have been developed to aid in the home monitoring of patients with pulmonary disease. The aim of this study was to investigate the technical validity and usability of the Air Next spirometer in pediatric patients.<h4>Methods</h4>Device vari  ...[more]

Similar Datasets

| S-EPMC9952128 | biostudies-literature
| S-EPMC9903956 | biostudies-literature
| S-EPMC8080268 | biostudies-literature
| S-EPMC8464351 | biostudies-literature
| 2726863 | ecrin-mdr-crc
| S-EPMC6853806 | biostudies-literature
| S-EPMC5491989 | biostudies-literature
| S-EPMC5763206 | biostudies-literature
| S-EPMC6154438 | biostudies-literature
| S-EPMC9443928 | biostudies-literature