Unknown

Dataset Information

0

Low-Dose, Contrast-Enhanced Mammography Compared to Contrast-Enhanced Breast MRI: A Feasibility Study.


ABSTRACT: Contrast-enhanced MRI (CE-MRI) is the most sensitive technique for breast cancer detection. Contrast-enhanced mammography (CEM) is emerging as a possible alternative to CE-MRI. PURPOSE:To evaluate the diagnostic performance of a low radiation dose contrast-enhanced mammography (L-CEM) in women with suspicious findings on conventional imaging compared to CE-MRI of the breast. STUDY TYPE:Prospective, single center. POPULATION:Women with suspicious findings on mammography, tomosynthesis, or ultrasound, and no contraindications for L-CEM or CE-MRI. Eighty women were included. FIELD STRENGTH/SEQUENCE:1.5 and 3T?CE-MRI, standard protocol for breast, with dedicated coils, according to international guidelines. L-CEM was performed using a dedicated prototype. ASSESSMENT:Three, off-site, blinded readers evaluated the images according to the BI-RADS lexicon in a randomized order, each in two separate reading sessions. Histology served as a gold standard. STATISTICAL TEST:Lesion detection rate, sensitivity, specificity, and negative and positive predictive values (NPV, PPV) were calculated and compared with multivariate statistics. RESULTS:Included were 80 women (mean age, 54.3?years ±11.2 standard deviation) with 93 lesions (32 benign, 61 malignant). The detection rate was significantly higher with CE-MRI (92.5-94.6%; L-CEM 79.6-91.4%, P = 0.014). Sensitivity (L-CEM 65.6-90.2%; CE-MRI 83.6-93.4%, P = 0.086) and NPV (L-CEM 59.6-71.4%; CE-MRI 63.0-76.5%, P = 0.780) did not differ between the modalities. Specificity (L-CEM 46.9-96.9%; CE-MRI 37.5-53.1%, P = 0.001) and PPV (L-CEM 76.4-97.6%; CE-MRI 73.3-77.3%, P = 0.007) were significantly higher with L-CEM. Variations between readers were significant for sensitivity and NPV. The accuracy of L-CEM was as good as CE-MRI (75.3-76.3% vs. 72.0-75.3%, P = 0.514). DATA CONCLUSION:L-CEM showed a high sensitivity and accuracy in women with suspicious findings on conventional imaging. Compared to CE-MRI, L-CEM has the potential to increase specificity and PPV. L-CEM might help to reduce false-positive biopsies while obtaining sensitivity comparable to that of CE-MRI LEVEL OF EVIDENCE: 1 TECHNICAL EFFICACY STAGE: 2 J. Magn. Reson. Imaging 2020;52:589-595.

SUBMITTER: Clauser P 

PROVIDER: S-EPMC7496227 | biostudies-literature | 2020 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Low-Dose, Contrast-Enhanced Mammography Compared to Contrast-Enhanced Breast MRI: A Feasibility Study.

Clauser Paola P   Baltzer Pascal A T PAT   Kapetas Panagiotis P   Hoernig Mathias M   Weber Michael M   Leone Federica F   Bernathova Maria M   Helbich Thomas H TH  

Journal of magnetic resonance imaging : JMRI 20200214 2


Contrast-enhanced MRI (CE-MRI) is the most sensitive technique for breast cancer detection. Contrast-enhanced mammography (CEM) is emerging as a possible alternative to CE-MRI.<h4>Purpose</h4>To evaluate the diagnostic performance of a low radiation dose contrast-enhanced mammography (L-CEM) in women with suspicious findings on conventional imaging compared to CE-MRI of the breast.<h4>Study type</h4>Prospective, single center.<h4>Population</h4>Women with suspicious findings on mammography, tomo  ...[more]

Similar Datasets

| S-EPMC10902320 | biostudies-literature
| S-EPMC7243325 | biostudies-literature
| S-EPMC7400681 | biostudies-literature
| S-EPMC7564182 | biostudies-literature
| S-EPMC9925630 | biostudies-literature
| S-EPMC7047570 | biostudies-literature
| S-EPMC8195270 | biostudies-literature
| S-EPMC9956946 | biostudies-literature
| S-EPMC9406751 | biostudies-literature
| S-EPMC10047016 | biostudies-literature