Unknown

Dataset Information

0

Barriers and aids to routine neuromuscular monitoring and consistent reversal practice-A qualitative study.


ABSTRACT: BACKGROUND:Neuromuscular monitoring is recommended whenever a neuromuscular blocking agent is administered, but surveys have demonstrated inconsistent monitoring practices. Using qualitative methods, we aimed to explore barriers and aids to routine neuromuscular monitoring and consistent reversal practice. METHODS:Focus group interviews were conducted to obtain insights into the thoughts and attitudes of individual anaesthetists, as well as the influence of colleagues and department culture. Interviews were conducted at five Danish and one US hospital. Data were analysed using template analysis. RESULTS:Danish anaesthetists used objective neuromuscular monitoring when administering a non-depolarizing relaxant, but had challenges with calibrating the monitor and sometimes interpreting measurements. Residents from the US institution used subjective neuromuscular monitoring, objective neuromuscular monitoring was generally not available and most had not used it. Danish anaesthetists used neuromuscular monitoring to assess readiness for extubation, whereas US residents used subjective neuromuscular monitoring, clinical tests like 5-second head lift and ventilatory parameters. The residents described a lack of consensus between senior anaesthesiologists in reversal practice and monitoring use. Barriers to consistent and correct neuromuscular monitoring identified included unreliable equipment, time pressure, need for training, misconceptions about pharmacokinetics of neuromuscular blocking agents and residual block, lack of standards and guidelines and departmental culture. CONCLUSION:Using qualitative methods, we found that though Danish anaesthetists generally apply objective neuromuscular monitoring routinely and residents at the US institution often apply subjective neuromuscular monitoring, barriers to consistent and correct use still exist.

SUBMITTER: Thomsen JLD 

PROVIDER: S-EPMC7497053 | biostudies-literature | 2020 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Barriers and aids to routine neuromuscular monitoring and consistent reversal practice-A qualitative study.

Thomsen Jakob L D JLD   Marty Adrian P AP   Wakatsuki Shin S   Macario Alex A   Tanaka Pedro P   Gätke Mona R MR   Østergaard Doris D  

Acta anaesthesiologica Scandinavica 20200506 8


<h4>Background</h4>Neuromuscular monitoring is recommended whenever a neuromuscular blocking agent is administered, but surveys have demonstrated inconsistent monitoring practices. Using qualitative methods, we aimed to explore barriers and aids to routine neuromuscular monitoring and consistent reversal practice.<h4>Methods</h4>Focus group interviews were conducted to obtain insights into the thoughts and attitudes of individual anaesthetists, as well as the influence of colleagues and departme  ...[more]

Similar Datasets

| S-EPMC6686992 | biostudies-literature
| S-EPMC8317140 | biostudies-literature
| S-EPMC4312631 | biostudies-literature
| S-EPMC5695436 | biostudies-literature
| S-EPMC9976991 | biostudies-literature
| S-EPMC7190918 | biostudies-literature
| S-EPMC8378703 | biostudies-literature
| S-EPMC10161985 | biostudies-literature
| S-EPMC8447588 | biostudies-literature
| S-EPMC6572934 | biostudies-literature