Feasibility of a customizable training environment for neurointerventional skills assessment.


ABSTRACT: OBJECTIVE:To meet increasing demands to train neuroendovascular techniques, we developed a dedicated simulator applying individualized three-dimensional intracranial aneurysm models ('HANNES'; Hamburg Anatomic Neurointerventional Endovascular Simulator). We hypothesized that HANNES provides a realistic and reproducible training environment to practice coil embolization and to exemplify disparities between neurointerventionalists, thus objectively benchmarking operators at different levels of experience. METHODS:Six physicians with different degrees of neurointerventional procedural experience were recruited into a standardized training protocol comprising catheterization of two internal carotid artery (ICA) aneurysms and one basilar tip aneurysm, followed by introduction of one framing coil into each aneurysm and finally complete coil embolization of one determined ICA aneurysm. The level of difficulty increased with every aneurysm. Fluoroscopy was recorded and assessed for procedural characteristics and adverse events. RESULTS:Physicians were divided into inexperienced and experienced operators, depending on their experience with microcatheter handling. Mean overall catheterization times increased with difficulty of the aneurysm model. Inexperienced operators showed longer catheterization times (median; IQR: 47; 30-84s) than experienced operators (21; 13-58s, p = 0.011) and became significantly faster during the course of the attempts (rho = -0.493, p = 0.009) than the experienced physicians (rho = -0.318, p = 0.106). Number of dangerous maneuvers throughout all attempts was significantly higher for inexperienced operators (median; IQR: 1.0; 0.0-1.5) as compared to experienced operators (0.0; 0.0-1.0, p = 0.014). CONCLUSION:HANNES represents a modular neurointerventional training environment for practicing aneurysm coil embolization in vitro. Objective procedural metrics correlate with operator experience, suggesting that the system could be useful for assessing operator proficiency.

SUBMITTER: Nawka MT 

PROVIDER: S-EPMC7498089 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Feasibility of a customizable training environment for neurointerventional skills assessment.

Nawka Marie Teresa MT   Hanning Uta U   Guerreiro Helena H   Flottmann Fabian F   Van Horn Noel N   Buhk Jan-Hendrik JH   Fiehler Jens J   Frölich Andreas Maximilian AM  

PloS one 20200917 9


<h4>Objective</h4>To meet increasing demands to train neuroendovascular techniques, we developed a dedicated simulator applying individualized three-dimensional intracranial aneurysm models ('HANNES'; Hamburg Anatomic Neurointerventional Endovascular Simulator). We hypothesized that HANNES provides a realistic and reproducible training environment to practice coil embolization and to exemplify disparities between neurointerventionalists, thus objectively benchmarking operators at different level  ...[more]

Similar Datasets

| S-EPMC3771167 | biostudies-other
| S-EPMC6623970 | biostudies-literature
| S-EPMC6342345 | biostudies-literature
| S-EPMC3912701 | biostudies-literature
| S-EPMC9362415 | biostudies-literature
| S-EPMC3794677 | biostudies-literature
| S-EPMC5135413 | biostudies-literature
| S-EPMC7779756 | biostudies-literature
| S-EPMC8019211 | biostudies-literature
| S-EPMC6314809 | biostudies-literature