Unknown

Dataset Information

0

Kinetic patterns of benign and malignant breast lesions on contrast enhanced digital mammogram.


ABSTRACT: PURPOSE:To evaluate the kinetic patterns of benign and malignant breast lesions using contrast-enhanced digital mammogram (CEDM). METHODS:Women with suspicious breast lesions on mammography or ultrasound were enrolled. Single-view mediolateral oblique (MLO) CEDM of an affected breast was acquired at 2, 3, 4, 7, and 10 min after injection of contrast agent. Three readers visually and semi-quantitatively analyzed the enhancement of suspicious lesions. The kinetic pattern of each lesion was classified as persistent, plateau, or washout over two time intervals, 2-4 min and 2-10 min, by comparing the signal intensity at the first time interval with that at the second. RESULTS:There were 73 malignant and 75 benign lesions in 148 patients (mean age: 52 years). Benign and malignant breast lesions showed the highest signal intensity at 3 min and 2 min, respectively. Average areas under receiver operating characteristic (ROC) curve for diagnostic accuracy based on lesion enhancement at different time points were 0.73 at 2 min, 0.72 at 3 min, 0.69 at 4 min, 0.67 at 7 min, and 0.64 at 10 min. Diagnostic performance was significantly better at 2, 3, and 4 min than at 7 and 10 min (all p < 0.05). A washout kinetic pattern was significantly associated with malignant lesions at 2-4 min and 2-10 min frames according to two of the three readers' interpretations (all p ? 0.001). CONCLUSION:Applications of optimal time intervals and kinetic patterns show promise in differentiation of benign and malignant breast lesions on CEDM.

SUBMITTER: Huang JS 

PROVIDER: S-EPMC7498093 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Kinetic patterns of benign and malignant breast lesions on contrast enhanced digital mammogram.

Huang Jer-Shyung JS   Pan Huay-Ben HB   Yang Tsung-Lung TL   Hung Bao-Hui BH   Chiang Chia-Ling CL   Tsai Meng-Yuan MY   Chou Chen-Pin CP  

PloS one 20200917 9


<h4>Purpose</h4>To evaluate the kinetic patterns of benign and malignant breast lesions using contrast-enhanced digital mammogram (CEDM).<h4>Methods</h4>Women with suspicious breast lesions on mammography or ultrasound were enrolled. Single-view mediolateral oblique (MLO) CEDM of an affected breast was acquired at 2, 3, 4, 7, and 10 min after injection of contrast agent. Three readers visually and semi-quantitatively analyzed the enhancement of suspicious lesions. The kinetic pattern of each les  ...[more]

Similar Datasets

| S-EPMC8566652 | biostudies-literature
| S-EPMC4824432 | biostudies-literature
| S-EPMC7243325 | biostudies-literature
| S-EPMC4357383 | biostudies-literature