Dual Oxygen and Temperature Luminescence Learning Sensor with Parallel Inference.


ABSTRACT: A well-known approach to the optical measure of oxygen is based on the quenching of luminescence by molecular oxygen. The main challenge for this measuring method is the determination of an accurate mathematical model for the sensor response. The reason is the dependence of the sensor signal from multiple parameters (like oxygen concentration and temperature), which are cross interfering in a sensor-specific way. The common solution is to measure the different parameters separately, for example, with different sensors. Then, an approximate model is developed where these effects are parametrized ad hoc. In this work, we describe a new approach for the development of a learning sensor with parallel inference that overcomes all these difficulties. With this approach we show how to generate automatically and autonomously a very large dataset of measurements and how to use it for the training of the proposed neural-network-based signal processing. Furthermore, we demonstrate how the sensor exploits the cross-sensitivity of multiple parameters to extract them from a single set of optical measurements without any a priori mathematical model with unprecedented accuracy. Finally, we propose a completely new metric to characterize the performance of neural-network-based sensors, the Error Limited Accuracy. In general, the methods described here are not limited to oxygen and temperature sensing. They can be similarly applied for the sensing with multiple luminophores, whenever the underlying mathematical model is not known or too complex.

SUBMITTER: Venturini F 

PROVIDER: S-EPMC7506703 | biostudies-literature | 2020 Aug

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dual Oxygen and Temperature Luminescence Learning Sensor with Parallel Inference.

Venturini Francesca F   Michelucci Umberto U   Baumgartner Michael M  

Sensors (Basel, Switzerland) 20200828 17


A well-known approach to the optical measure of oxygen is based on the quenching of luminescence by molecular oxygen. The main challenge for this measuring method is the determination of an accurate mathematical model for the sensor response. The reason is the dependence of the sensor signal from multiple parameters (like oxygen concentration and temperature), which are cross interfering in a sensor-specific way. The common solution is to measure the different parameters separately, for example,  ...[more]

Similar Datasets

| S-EPMC3878311 | biostudies-literature
| S-EPMC6648012 | biostudies-literature
| S-EPMC6214802 | biostudies-literature
| S-EPMC8685671 | biostudies-literature
| S-EPMC6642144 | biostudies-literature
| S-EPMC7037827 | biostudies-literature
| S-EPMC4640693 | biostudies-literature
| S-EPMC10974837 | biostudies-literature
| S-EPMC9579593 | biostudies-literature
| S-EPMC7033239 | biostudies-literature