Thermal imaging dataset from composite material academic samples inspected by pulsed thermography.


ABSTRACT: This paper presents a thermal imaging dataset from composite material samples (carbon and glass fiber reinforced plastic) that were inspected by pulsed thermography with the goal of detecting and characterizing subsurface defective zones (Teflon inserts representing delaminations between plies). The pulsed thermography experiment was applied to 6 academic plates (inspected from both sides) all having the dimensions of 300 mm x 300 mm x 2 mm and same distribution of defects but made of different materials: three plates on carbon fiber-reinforced plastic (CFRP) and three plates made on glass fiber reinforced plastic (GFRP) specimens with three different geometries: planar, curved and trapezoidal. Each plate contains 25 inserts having length/depth ratios between 1.7 and 75. Two FX60 BALCAR photographic flashes (6.2 kJ per flash) were used to generate the heat pulse (2 ms duration), an X6900 FLIR infrared camera using ResearchIR software to record the thermal images and a custom-built software/control unit to synchronize data recording with pulse generation. Finally, the dataset proposed consists of 12 sequences of approximately 2000 images of 512?×?512 pixels each.

SUBMITTER: Erazo-Aux J 

PROVIDER: S-EPMC7508994 | biostudies-literature | 2020 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Thermal imaging dataset from composite material academic samples inspected by pulsed thermography.

Erazo-Aux Jorge J   Loaiza-Correa Humberto H   Restrepo-Giron Andres David AD   Ibarra-Castanedo Clemente C   Maldague Xavier X  

Data in brief 20200914


This paper presents a thermal imaging dataset from composite material samples (carbon and glass fiber reinforced plastic) that were inspected by pulsed thermography with the goal of detecting and characterizing subsurface defective zones (Teflon inserts representing delaminations between plies). The pulsed thermography experiment was applied to 6 academic plates (inspected from both sides) all having the dimensions of 300 mm x 300 mm x 2 mm and same distribution of defects but made of different  ...[more]

Similar Datasets

| S-EPMC6404046 | biostudies-literature
| S-EPMC6304129 | biostudies-literature
| S-EPMC6829452 | biostudies-literature
| S-EPMC9055355 | biostudies-literature
| S-EPMC8825608 | biostudies-literature
| PRJNA436601 | ENA
| S-EPMC8165393 | biostudies-literature
| S-EPMC8897477 | biostudies-literature
| S-EPMC7699644 | biostudies-literature
| S-EPMC5458928 | biostudies-other