Unknown

Dataset Information

0

Detection of advanced colorectal neoplasia and relative colonoscopy workloads using quantitative faecal immunochemical tests: an observational study exploring the effects of simultaneous adjustment of both sample number and test positivity threshold.


ABSTRACT: OBJECTIVE:When screening for colorectal cancer (CRC) using quantitative faecal immunochemical tests (FIT), test parameters requiring consideration are the faecal haemoglobin concentration (f-Hb) positivity cut-off and the number of stools sampled. This observational study explored variation in f-Hb between samples and the relationship between sensitivity for advanced neoplasia (AN, cancer or advanced adenoma) and colonoscopy workload across a range of independently-adjusted parameter combinations. DESIGN:Quantitative FIT data (OC-Sensor) were accessed from individuals undergoing personalised colonoscopic screening with an offer of 2-sample FIT in the intervening years. We estimated variation in f-Hb between samples in 12?710 completing 2-sample FIT, plus test positivity rates (colonoscopy workload) and sensitivity for AN according to parameter combinations in 4037 instances where FIT was done in the year preceding colonoscopy. RESULTS:There was large within-subject variability between samples, with the ratio for the second to the first sample f-Hb ranging up to 18-fold for all cases, and up to 56-fold for AN cases. Sensitivity for AN was greatest at lower f-Hb cut-offs and/or using 2-sample FIT. Colonoscopy workload varied according to how parameters were combined. Using different cut-offs for 1-sample FIT and 2-sample FIT to return similar sensitivity, workload was less with 2-sample FIT when the sensitivity goal exceeded 35%. CONCLUSION:Variation in f-Hb between samples is such that both parameters are crucial determinants of sensitivity and workload; independent adjustment of each should be considered. The 2-sample FIT approach is best for detecting advanced adenomas as well as CRC provided that the colonoscopy workload is feasible.

SUBMITTER: Young GP 

PROVIDER: S-EPMC7526287 | biostudies-literature | 2020 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Detection of advanced colorectal neoplasia and relative colonoscopy workloads using quantitative faecal immunochemical tests: an observational study exploring the effects of simultaneous adjustment of both sample number and test positivity threshold.

Young Graeme P GP   Woodman Richard J RJ   Symonds Erin E  

BMJ open gastroenterology 20200901 1


<h4>Objective</h4>When screening for colorectal cancer (CRC) using quantitative faecal immunochemical tests (FIT), test parameters requiring consideration are the faecal haemoglobin concentration (f-Hb) positivity cut-off and the number of stools sampled. This observational study explored variation in f-Hb between samples and the relationship between sensitivity for advanced neoplasia (AN, cancer or advanced adenoma) and colonoscopy workload across a range of independently-adjusted parameter com  ...[more]

Similar Datasets

| S-EPMC11258152 | biostudies-literature
| S-EPMC6709777 | biostudies-literature
| S-EPMC3201938 | biostudies-literature
| S-EPMC6774435 | biostudies-literature
| S-EPMC8559494 | biostudies-literature
| S-EPMC3404596 | biostudies-literature
| S-EPMC8227954 | biostudies-literature
| S-EPMC6878177 | biostudies-literature
| S-EPMC6118361 | biostudies-literature
| S-EPMC6374854 | biostudies-other