Pre-clinical dose-ranging efficacy, pharmacokinetics, tissue biodistribution, and toxicity of a targeted contrast agent for MRI of amyloid deposition in Alzheimer's disease.


ABSTRACT: In these preclinical studies, we describe ADx-001, an A?-targeted liposomal macrocyclic gadolinium (Gd) imaging agent, for MRI of amyloid plaques. The targeting moiety is a novel lipid-PEG conjugated styryl-pyrimidine. An MRI-based contrast agent such as ADx-001 is attractive because of the lack of radioactivity, ease of distribution, long shelf life, and the prevalence of MRI scanners. Dose-ranging efficacy studies were performed on a 1 T MRI scanner using a transgenic APP/PSEN1 mouse model of Alzheimer's disease. ADx-001 was tested at 0.10, 0.15, and 0.20 mmol Gd/kg. Gold standard post-mortem amyloid immunostaining was used for the determination of sensitivity and specificity. ADx-001 toxicity was evaluated in rats and monkeys at doses up to 0.30 mmol Gd/kg. ADx-001 pharmacokinetics were determined in monkeys and its tissue distribution was evaluated in rats. ADx-001-enhanced MRI demonstrated significantly higher (p?

SUBMITTER: Badachhape AA 

PROVIDER: S-EPMC7527957 | biostudies-literature | 2020 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Pre-clinical dose-ranging efficacy, pharmacokinetics, tissue biodistribution, and toxicity of a targeted contrast agent for MRI of amyloid deposition in Alzheimer's disease.

Badachhape Andrew A AA   Working Peter K PK   Srivastava Mayank M   Bhandari Prajwal P   Stupin Igor V IV   Devkota Laxman L   Tanifum Eric A EA   Annapragada Ananth V AV   Ghaghada Ketan B KB  

Scientific reports 20200930 1


In these preclinical studies, we describe ADx-001, an Aβ-targeted liposomal macrocyclic gadolinium (Gd) imaging agent, for MRI of amyloid plaques. The targeting moiety is a novel lipid-PEG conjugated styryl-pyrimidine. An MRI-based contrast agent such as ADx-001 is attractive because of the lack of radioactivity, ease of distribution, long shelf life, and the prevalence of MRI scanners. Dose-ranging efficacy studies were performed on a 1 T MRI scanner using a transgenic APP/PSEN1 mouse model of  ...[more]

Similar Datasets

| S-EPMC4249580 | biostudies-literature
| S-EPMC5071101 | biostudies-literature
| S-EPMC8981495 | biostudies-literature
| S-EPMC7599822 | biostudies-literature
| S-EPMC6491262 | biostudies-literature
| S-EPMC4260332 | biostudies-literature
| S-EPMC3060273 | biostudies-literature
| S-EPMC4776747 | biostudies-literature
| S-EPMC7028485 | biostudies-literature
| S-EPMC3369710 | biostudies-literature