Unknown

Dataset Information

0

Multiple breath washout in bronchiectasis clinical trials: is it feasible?


ABSTRACT: Background:Evaluation of multiple breath washout (MBW) set-up including staff training, certification and central "over-reading" for data quality control is essential to determine the feasibility of MBW in future bronchiectasis studies. Aims:To assess the outcomes of a MBW training, certification and central over-reading programme. Methods:MBW training and certification was conducted in European sites collecting lung clearance index (LCI) data in the BronchUK Clinimetrics and/or i-BEST-1 studies. The blended training programme included the use of an eLearning tool and a 1-day face-to-face session. Sites submitted MBW data to trained central over-readers who determined validity and quality. Results:Thirteen training days were delivered to 56 participants from 22 sites. Of 22 sites, 18 (82%) were MBW naïve. Participant knowledge and confidence increased significantly (p<0.001). By the end of the study recruitment, 15 of 22 sites (68%) had completed certification with a mean (range) time since training of 6.2 (3-14) months. In the BronchUK Clinimetrics study, 468 of 589 (79%) tests met the quality criteria following central over-reading, compared with 137 of 236 (58%) tests in the i-BEST-1 study. Conclusions:LCI is feasible in a bronchiectasis multicentre clinical trial setting; however, consideration of site experience in terms of training as well as assessment of skill drift and the need for re-training may be important to reduce time to certification and optimise data quality. Longer times to certification, a higher percentage of naïve sites and patients with worse lung function may have contributed to the lower success rate in the i-BEST-1 study.

SUBMITTER: O'Neill K 

PROVIDER: S-EPMC7553113 | biostudies-literature | 2020 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications


<h4>Background</h4>Evaluation of multiple breath washout (MBW) set-up including staff training, certification and central "over-reading" for data quality control is essential to determine the feasibility of MBW in future bronchiectasis studies.<h4>Aims</h4>To assess the outcomes of a MBW training, certification and central over-reading programme.<h4>Methods</h4>MBW training and certification was conducted in European sites collecting lung clearance index (LCI) data in the BronchUK Clinimetrics a  ...[more]

Similar Datasets

| S-EPMC4500401 | biostudies-literature
| S-EPMC4909265 | biostudies-literature
| S-EPMC4357571 | biostudies-literature
| S-EPMC9565421 | biostudies-literature
| S-EPMC2092467 | biostudies-literature
| S-EPMC8048067 | biostudies-literature
| S-EPMC7682699 | biostudies-literature
| S-EPMC6306708 | biostudies-literature
| S-EPMC5725793 | biostudies-literature
| S-EPMC4043749 | biostudies-literature