Feasibility of CardioSecur®, a Mobile 4-Electrode/22-Lead ECG Device, in the Prehospital Emergency Setting.


ABSTRACT: Background: This study explores the application of CardioSecur® (CS-ECG), a hand-held 4-electrode/22-lead ECG-device, in comparison with conventional 12-lead electrocardiogram (c12L-ECG) in patients with acute chest pain in the prehospital emergency setting. Methods: CS-ECG systems were provided for two physician-staffed emergency ambulances and parallel recordings of c12L-ECG and CS-ECG were obtained from all patients with acute chest pain. Treating emergency physicians were asked to evaluate the CS-ECG system with a standardized questionnaire. Following study completion, acquired ECGs were analyzed separately by two independent cardiologists blinded to all other medical records. Results: Over a period of 20 months a total of 203 patients were included in our study. According to a standardized questionnaire, 79% of emergency medical professionals preferred application of CS-ECG, with 87% of teams judging CS-ECG to be beneficial for patients. Morover, 79% of physicians reported a reduction in time to definitive diagnosis with implementation of CS-ECG. The majority of professional users attested user-friendliness and feasibility of CS-ECG in terms of easy general handling (94%), application (93%), and placement of electrodes (98%). During prehospital triage, both c12L-ECG and CS-ECG correctly identified 31 (91%) patients with ST-elevation myocardial infarction (STEMI). Conclusion: In this first pilot study, implementation of the CardioSecur®-ECG system in the prehospital emergency setting demonstrated feasibility and user-friendliness so that emergency teams generally preferred CS-ECG to c12L-ECG. Diagnostic yield of CS-ECG was similar to c12L-ECG recordings.

SUBMITTER: Spaich S 

PROVIDER: S-EPMC7581708 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Feasibility of CardioSecur®, a Mobile 4-Electrode/22-Lead ECG Device, in the Prehospital Emergency Setting.

Spaich Sebastian S   Kern Hanna H   Zelniker Thomas A TA   Stiepak Jan J   Gabel Michael M   Popp Erik E   Katus Hugo A HA   Preusch Michael R MR  

Frontiers in cardiovascular medicine 20201009


<b>Background:</b> This study explores the application of CardioSecur® (CS-ECG), a hand-held 4-electrode/22-lead ECG-device, in comparison with conventional 12-lead electrocardiogram (c12L-ECG) in patients with acute chest pain in the prehospital emergency setting. <b>Methods:</b> CS-ECG systems were provided for two physician-staffed emergency ambulances and parallel recordings of c12L-ECG and CS-ECG were obtained from all patients with acute chest pain. Treating emergency physicians were asked  ...[more]

Similar Datasets

| S-EPMC8700180 | biostudies-literature
| S-EPMC6603515 | biostudies-literature
| S-EPMC7050507 | biostudies-literature
| S-EPMC3599067 | biostudies-literature
| S-EPMC5992078 | biostudies-literature
| S-EPMC5439232 | biostudies-other
| S-EPMC9949528 | biostudies-literature
| S-EPMC8805596 | biostudies-literature
| S-EPMC7917757 | biostudies-literature
| S-EPMC4366173 | biostudies-literature