Unknown

Dataset Information

0

Evaluation of Solvents Used as Keepers in the Determination of Organic Pollutants by GC/MS.


ABSTRACT: Solvent evaporation is often used in the sample preparation procedure for the determination of organic pollutants such as polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and organic pesticides. Because of the loss of analyte during this step, a high-boiling solvent, i.e., a keeper, is often added to the extract before evaporation. However, there are almost no basic studies found in the literature on the selection of keepers for the appropriate type of analytes (keepers are usually selected only on the basis of information provided by various recommendations). In this work, the effect of several keepers (isooctane, toluene, nonane, octanol, dodecane) on the recovery of various analytes (PAHs, PCBs, organic pesticides) was evaluated (during evaporation in a stream of nitrogen, at 40 °C). The analysis of the results obtained for the tested compounds shows that 1-octanol is a universal keeper for compounds with low volatility, i.e., PCBs (average recovery: 97.6%), organochlorine pesticides (average recovery: 95.0%), organophosphorus pesticides (OPPs; average recovery: 99.7%) and higher mass PAHs (average recovery: 91.9%). The use of isooctane as a keeper yields high recoveries for PAHs, regardless of their volatility (average recovery: 95.5%). When using 1-octanol or dodecane as a keeper, the reversed solvent effect (during GC analysis) was noted in relation to volatile analytes causing the distortion of their peaks. Additionally, the phenomenon of loss of some analytes (e.g., OPPs) was observed during evaporation without heating the vials. However, in the case of PCBs, organochlorine pesticides (OCPs) and o-hydroxybiphenyl, evaporation under such conditions yields recoveries greater than or equal to 90.0%. The results presented in this work can help in finding a suitable keeper for a specific group of analytes or an alternative to the commonly used one, especially in the case of recovery problems.

SUBMITTER: Dabrowski L 

PROVIDER: S-EPMC7582485 | biostudies-literature | 2020 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of Solvents Used as Keepers in the Determination of Organic Pollutants by GC/MS.

Dąbrowski Łukasz Ł  

Molecules (Basel, Switzerland) 20200925 19


Solvent evaporation is often used in the sample preparation procedure for the determination of organic pollutants such as polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyls (PCBs) and organic pesticides. Because of the loss of analyte during this step, a high-boiling solvent, i.e., a keeper, is often added to the extract before evaporation. However, there are almost no basic studies found in the literature on the selection of keepers for the appropriate type of analytes (keepers  ...[more]

Similar Datasets

| S-EPMC5541126 | biostudies-other
| S-EPMC8724214 | biostudies-literature
| S-EPMC7305521 | biostudies-literature
2011-10-06 | GSE32593 | GEO