Unknown

Dataset Information

0

Numerical investigation of aerosol transport in a classroom with relevance to COVID-19.


ABSTRACT: The present study investigates aerosol transport and surface deposition in a realistic classroom environment using computational fluid-particle dynamics simulations. Effects of particle size, aerosol source location, glass barriers, and windows are explored. While aerosol transport in air exhibits some stochasticity, it is found that a significant fraction (24%-50%) of particles smaller than 15 µm exit the system within 15 min through the air conditioning system. Particles larger than 20 µm almost entirely deposit on the ground, desks, and nearby surfaces in the room. Source location strongly influences the trajectory and deposition distribution of the exhaled aerosol particles and affects the effectiveness of mitigation measures such as glass barriers. Glass barriers are found to reduce the aerosol transmission of 1 µm particles from the source individual to others separated by at least 2.4 m by ?92%. By opening windows, the particle exit fraction can be increased by ?38% compared to the case with closed windows and reduces aerosol deposition on people in the room. On average, ?69% of 1 µm particles exit the system when the windows are open.

SUBMITTER: Abuhegazy M 

PROVIDER: S-EPMC7583363 | biostudies-literature | 2020 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Numerical investigation of aerosol transport in a classroom with relevance to COVID-19.

Abuhegazy Mohamed M   Talaat Khaled K   Anderoglu Osman O   Poroseva Svetlana V SV  

Physics of fluids (Woodbury, N.Y. : 1994) 20201001 10


The present study investigates aerosol transport and surface deposition in a realistic classroom environment using computational fluid-particle dynamics simulations. Effects of particle size, aerosol source location, glass barriers, and windows are explored. While aerosol transport in air exhibits some stochasticity, it is found that a significant fraction (24%-50%) of particles smaller than 15 <i>µ</i>m exit the system within 15 min through the air conditioning system. Particles larger than 20  ...[more]

Similar Datasets

| S-EPMC7405119 | biostudies-literature
| S-EPMC7094279 | biostudies-literature
| S-EPMC8250912 | biostudies-literature
| S-EPMC10704378 | biostudies-literature
| S-BSST563 | biostudies-other
| S-EPMC4573894 | biostudies-other
| S-EPMC9490255 | biostudies-literature
| S-EPMC7937356 | biostudies-literature
| S-BSST416 | biostudies-other
| S-EPMC7329662 | biostudies-literature