Recombinase Polymerase Amplification Based Multiplex Lateral Flow Dipstick for Fast Identification of Duck Ingredient in Adulterated Beef.


ABSTRACT: Meat adulteration has become a global social problem. In order to protect consumers from meat adulteration, several methods have been developed to identify meat species. However, the conventional methods are labor-intensive, time-consuming and require instruments. In the present study, a rapid and visual method based on recombinase polymerase amplification (RPA) and multiplex lateral flow dipstick (MLFD) was developed to detect duck ingredient in adulterated beef. Using recombinase and strand displacement polymerase enable RPA to amplify different double-labeled DNA amplicons at room temperature, which can be further detected by MLFD. The whole reaction process can be finished within 35 min, and the results can be determined by naked eyes. As low as 5% of duck ingredient in adulterated beef can be easily measured. Moreover, we confirmed that our new method held good potential in the detection of commercially processed meat samples. In conclusion, this study reported a useful animal derived meat adulteration detection method, which have potential application in future.

SUBMITTER: Fu M 

PROVIDER: S-EPMC7601885 | biostudies-literature | 2020 Sep

REPOSITORIES: biostudies-literature

altmetric image

Publications

Recombinase Polymerase Amplification Based Multiplex Lateral Flow Dipstick for Fast Identification of Duck Ingredient in Adulterated Beef.

Fu Ming M   Zhang Quanwang Q   Zhou Xiang X   Liu Bang B  

Animals : an open access journal from MDPI 20200929 10


Meat adulteration has become a global social problem. In order to protect consumers from meat adulteration, several methods have been developed to identify meat species. However, the conventional methods are labor-intensive, time-consuming and require instruments. In the present study, a rapid and visual method based on recombinase polymerase amplification (RPA) and multiplex lateral flow dipstick (MLFD) was developed to detect duck ingredient in adulterated beef. Using recombinase and strand di  ...[more]

Similar Datasets

| S-EPMC9263184 | biostudies-literature
| S-EPMC8892114 | biostudies-literature
| S-EPMC5006264 | biostudies-literature
| S-EPMC7113848 | biostudies-literature
| S-EPMC7203717 | biostudies-literature
| S-EPMC9118145 | biostudies-literature
| S-EPMC10197247 | biostudies-literature
| S-EPMC10193322 | biostudies-literature
| S-EPMC7126596 | biostudies-literature
| S-EPMC7199787 | biostudies-literature