ABSTRACT: Purpose:Conventional hemodialysis (HD) treatment has an acceptable removal of small uremic molecules, but so-called "middle molecules" in the range of 0.5-60 kDa are poorly cleared with HD compared to a native kidney, which may contribute to morbidity in the dialysis population. Hemodiafiltration (HDF) has a better removal of middle molecules compared to HD but is technically demanding and requires well-functioning dialysis access. The newly introduced medium cutoff (MCO) filters have been developed to enhance middle molecule clearance in HD-mode. The aim of this study was to compare reduction ratios (RRs) of molecules with different molecular weights (0.06-150 kDa) during dialysis with MCO dialyzer (used in HD-mode) compared to online-hemodiafiltration (ol-HDF) treatment with a conventional high-flux dialyzer. Patients and Methods:This is a prospective controlled single-center cross-over study, including 16 patients in Malmö, Sweden. All patients had ongoing post-dilution ol-HDF treatment before the study. The study compared reduction ratios of small-, middle-, and large-sized molecules during a single 4h dialysis treatment with post-dilution ol-HDF (Polyflux 210H) to a 4h dialysis treatment with MCO dialyzer (Theranova 500) in HD-mode. Between treatments, the patients had a washout period of at least two weeks of their ordinary HDF treatment to reach their ordinary steady state. Results:ol-HDF had significantly higher RR for cystatin C (13 kDa), compared to MCO (RR 68.1 vs 65.8, p=0.003), during a 4h dialysis treatment (mean convection volume of 24.5 L for HDF, and mean Qb of 324 mL/min for HDF and 323 mL/min for MCO). There was no significant difference in the RR for other middle molecules, or for smaller or larger molecules. Conclusion:Overall, the RRs were comparable for ol-HDF and MCO-HD. There was a slightly higher RR of cystatin C (a small middle molecule) for HDF compared to MCO but no difference in other measured molecules.

SUBMITTER: Lindgren A 

PROVIDER: S-EPMC7602900 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Comparison of Hemodialysis Using a Medium Cutoff Dialyzer versus Hemodiafiltration: A Controlled Cross-Over Study.

Lindgren Anna A   Fjellstedt Erik E   Christensson Anders A  

International journal of nephrology and renovascular disease 20201027


<h4>Purpose</h4>Conventional hemodialysis (HD) treatment has an acceptable removal of small uremic molecules, but so-called "middle molecules" in the range of 0.5-60 kDa are poorly cleared with HD compared to a native kidney, which may contribute to morbidity in the dialysis population. Hemodiafiltration (HDF) has a better removal of middle molecules compared to HD but is technically demanding and requires well-functioning dialysis access. The newly introduced medium cutoff (MCO) filters have be  ...[more]

Similar Datasets

| S-EPMC7659077 | biostudies-literature
| S-EPMC9044098 | biostudies-literature
| S-EPMC6485708 | biostudies-literature
| S-EPMC8144214 | biostudies-literature
| S-EPMC7524751 | biostudies-literature
| S-EPMC4038634 | biostudies-literature
| S-EPMC10514899 | biostudies-literature
| S-EPMC7480550 | biostudies-literature
| S-EPMC8476308 | biostudies-literature