Unknown

Dataset Information

0

The Association Between Endotracheal Tube Size and Aspiration (During Flexible Endoscopic Evaluation of Swallowing) in Acute Respiratory Failure Survivors.


ABSTRACT:

Objectives

To determine whether a modifiable risk factor, endotracheal tube size, is associated with the diagnosis of postextubation aspiration in survivors of acute respiratory failure.

Design

Prospective cohort study.

Setting

ICUs at four academic tertiary care medical centers.

Patients

Two hundred ten patients who were at least 18 years old, admitted to an ICU, and mechanically ventilated with an endotracheal tube for longer than 48 hours were enrolled.

Interventions

Within 72 hours of extubation, all patients received a flexible endoscopic evaluation of swallowing examination that entailed administration of ice, thin liquid, thick liquid, puree, and cracker boluses. Patient demographics, treatment variables, and hospital outcomes were abstracted from the patient's medical records. Endotracheal tube size was independently selected by the patient's treating physicians.

Measurements and main results

For each flexible endoscopic evaluation of swallowing examination, laryngeal pathology was evaluated, and for each bolus, a Penetration Aspiration Scale score was assigned. Aspiration (Penetration Aspiration Scale score ≥ 6) was further categorized into nonsilent aspiration (Penetration Aspiration Scale score = 6 or 7) and silent aspiration (Penetration Aspiration Scale score = 8). One third of patients (n = 68) aspirated (Penetration Aspiration Scale score ≥ 6) on at least one bolus, 13.6% (n = 29) exhibited silent aspiration, and 23.8% (n = 50) exhibited nonsilent aspiration. In a multivariable analysis, endotracheal tube size (≤ 7.5 vs ≥ 8.0) was significantly associated with patients exhibiting any aspiration (Penetration Aspiration Scale score ≥ 6) (p = 0.016; odds ratio = 2.17; 95% CI 1.14-4.13) and with risk of developing laryngeal granulation tissue (p = 0.02).

Conclusions

Larger endotracheal tube size was associated with increased risk of aspiration and laryngeal granulation tissue. Using smaller endotracheal tubes may reduce the risk of postextubation aspiration.

SUBMITTER: Krisciunas GP 

PROVIDER: S-EPMC7644217 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC5481997 | biostudies-literature
| S-EPMC7674978 | biostudies-literature
| S-EPMC9753025 | biostudies-literature
| S-EPMC9335245 | biostudies-literature
| S-EPMC6689167 | biostudies-literature
| S-EPMC8647059 | biostudies-literature
| S-EPMC7593288 | biostudies-literature
| S-EPMC6104110 | biostudies-literature
| S-EPMC8080860 | biostudies-literature
| PRJEB15589 | ENA