Reproducibility of Fixed-luminance and Multi-luminance Flicker Electroretinography in Patients With Diabetic Retinopathy Using an Office-based Testing Paradigm.


ABSTRACT: BACKGROUND:We evaluated the reproducibility of office-based flicker electroretinography (ERG) in patients with nonproliferative diabetic retinopathy (NPDR). METHODS:An observational study was conducted in which ultra-widefield fluorescein angiography (UWF-FA) was performed on 20 patients with mild-to-moderate NPDR; images were graded by the Fundus Photography Reading Center (Department of Ophthalmology and Visual Sciences, University of Wisconsin, Madison, WI, USA). Fixed- and multi-luminance flicker ERG was repeated four times (greater than or equal to seven days apart). Recording consistency was assessed using intra-class correlation coefficients (ICCs), coefficients of variation, and Pearson correlations. RESULTS:82.5% and 17.5% of eyes had mild and moderate NPDR using UWF-FA; 90% of the angiograms were given a high confidence grade. Fixed-luminance phase values were highly reproducible (ICC: 0.949; P?

SUBMITTER: Wroblewski JJ 

PROVIDER: S-EPMC7645135 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Reproducibility of Fixed-luminance and Multi-luminance Flicker Electroretinography in Patients With Diabetic Retinopathy Using an Office-based Testing Paradigm.

Wroblewski John J JJ   McChancy Christa C   Pickel Kassandra K   Buterbaugh Hunter H   Wieland Tyler T   Gonzalez Alberto A  

Journal of diabetes science and technology 20191022 6


<h4>Background</h4>We evaluated the reproducibility of office-based flicker electroretinography (ERG) in patients with nonproliferative diabetic retinopathy (NPDR).<h4>Methods</h4>An observational study was conducted in which ultra-widefield fluorescein angiography (UWF-FA) was performed on 20 patients with mild-to-moderate NPDR; images were graded by the Fundus Photography Reading Center (Department of Ophthalmology and Visual Sciences, University of Wisconsin, Madison, WI, USA). Fixed- and mul  ...[more]

Similar Datasets

| S-EPMC8505480 | biostudies-literature
| S-EPMC10057432 | biostudies-literature
| S-EPMC6947741 | biostudies-literature
| S-EPMC7612750 | biostudies-literature
| S-EPMC5364250 | biostudies-literature
| S-EPMC9527330 | biostudies-literature
| S-EPMC5427140 | biostudies-literature
| S-EPMC9467443 | biostudies-literature
| S-EPMC4682144 | biostudies-other
| S-EPMC4853922 | biostudies-literature