Project description:Video 1This video is our description of use of the novel dynamic rigidizing overtube in a challenging colonoscopy case in which looping was causing significant bradycardia and inability to advance the colonoscope to the cecum. The rigidizing overtube, through sequential cycles of its flexible and rigidized state, allowed for easy movement of the colonoscope to the cecum.
Project description:AIM:To evaluate the ability of PillCamColon2 to visualize colonic segments missed by incomplete optical colonoscopy (OC) and to assess the diagnostic yield. METHODS:This prospective multicentre study included 81 patients from nine centres who underwent second-generation colon capsule endoscopy (CCE) following incomplete OC performed by an experienced gastroenterologist (> 1000 colonoscopies). Patients with stenosis were excluded. According to patient preferences, CCE was performed the following day (protocol A) after staying on clear liquids and 0.75 L Moviprep in the morning or within 30 d after new split-dose Moviprep (protocol B). Boosts consisted of 0.75 L and 0.25 L Moviprep, and phospho-soda was given as a rescue if the capsule was not excreted after seven hours. RESULTS:Seventy-four patients were analysed (51% of them in group A; 49% in group B). Bowel cleansing was adequate in 67% of cases, and CCE could visualize colonic segments missed by incomplete colonoscopy in 90% of patients under protocol A and 97% of patients under protocol B (P = 0.35, n.s.). Significant polyps including adenocarcinoma were detected in 24% of cases. Detection rates for all polyps and significant polyps per patient were similar in both protocols. Polyps were found predominantly in the right colon (86%) in segments that were not reached by OC. Extracolonic findings - such as reflux esophagitis, suspected Barrett esophagus, upper GI-bleeding, gastric polyps, gastric erosions and angiectasia - were detected in eight patients. PillCamColon2 capsule was retained in the ileum of one patient (1.4%) without symptoms and removed during an uneventful resection for unknown Crohn's disease that was diagnosed as the cause of anemia, which was the indication for colonoscopy. CCE was well tolerated. One patient suffered from self-limiting vomiting after consuming the phospho-soda. CONCLUSION:Second-generation CCE using a low-volume preparation is useful after incomplete OC, and it allows for the detection of additional relevant findings, but cleansing efficiency could be improved.
Project description:BackgroundGuidelines suggest computed tomography colonography (CTC) following incomplete optical colonoscopy (OC). Colon capsule endoscopies (CCE) have been suggested as an alternative, although completion rates have been unsatisfactory. Introduction of artificial intelligence (AI)-based localization algorithms of the camera capsules may enable identification of incomplete CCE investigations overlapping with incomplete OCs.ObjectiveThe study aims to investigate relative sensitivity of CCE compared with CTC following incomplete OC, investigate the completion rate when combining results from the incomplete OC and CCE, and develop a forward-tracking algorithm ensuring a safe completeness of combined investigations.MethodsIn this prospective paired study, patients with indication for CTC following incomplete OC were included for CCE and CTC. Location of CCE abortion and OC abortion were registered to identify complete combined investigations. AI-based algorithm for localization of capsules were developed reconstructing the passage of the colon.ResultsIn 237 individuals with CTC indication; 105 were included, of which 97 underwent both a CCE and CTC. CCE was complete in 66 (68%). Including CCEs which reached most oral point of incomplete OC, 73 (75%) had complete colonic investigations; 78 (80%) had conclusive investigations. Relative sensitivity of CCE compared with CTC was 2.67 (95% confidence interval (CI) 1.76;4.04) for polyps >5 mm and 1.91 (95% CI 1.18;3.09) for polyps >9 mm. An AI-based algorithm was developed.ConclusionSensitivity of CCE following incomplete OC was superior to CTC. Introducing and improving algorithm-based localization of capsule abortion may increase identification of overall complete investigation rates following incomplete OC.ClinicalTrials.gov identifier: NCT02826993.
Project description:Background and study aims A significant percentage of colonoscopies remain incomplete because of failure to intubate the cecum. The motorized spiral enteroscope (MSE) technique, originally developed for deep small bowel enteroscopy, may be an effective alternative technique in cases of incomplete examination of abnormally long colons (dolichocolon). We prospectively evaluated the success rate of cecal intubation, safety and the therapeutic consequences of using MSE after incomplete conventional colonoscopy. Patients and methods A total of 36 consecutive patients with an indication for diagnostic and/or therapeutic colonoscopy were prospectively enrolled in this multicenter trial. All patients had undergone at least one incomplete colonoscopy attributed to abnormally long colons. Patients with incomplete colonoscopy due to stenosis were excluded. Results Twenty-two men and 14 women (median age 66 years, range 35-82) were enrolled. Median procedure time was 30 minutes (range 16-50). Cecal intubation rate was 100 % and median cecal intubation time was 10 minutes (range 4-30). Abnormalities, mostly neoplastic lesions, were detected in 23 of 36 patients, corresponding to a diagnostic yield of 64 %. All these findings were in the right side of the colon and had not been described by the antecedent incomplete coloscopy. No adverse events occurred. Conclusions In case of a difficult and long colon, MSE is safe and effective for diagnostic and therapeutic colonoscopy. It may provide an attractive solution to accomplish completeness of previous incomplete colonoscopies in these patients.
Project description:Metagenomics analysis of biopsy-derived colonic and terminal ileal mucosa associated microbiota in healthy individuals from a population-based study
Project description:BACKGROUND: Concerns about the risk of bowel perforation for same-day computed tomography colonography (CTC) following an incomplete colonoscopy with polypectomy may lead to unnecessarily postponing the CTC. OBJECTIVE: The objective of this article is to describe the complications including colon perforations associated with same-day CTC in a cohort who had polypectomies but an incomplete colonoscopy. DESIGN: We conducted a retrospective study. SETTING: Our study took place in a single, tertiary referral center. PATIENTS: We studied consecutive patients who had CTC the same day as an incomplete colonoscopy with polypectomy. INTERVENTIONS: Interventions included optical colonoscopy (OC), endoscopic polypectomies, and same-day CTC. MAIN OUTCOME MEASUREMENTS: Our main outcome measurements included perforation rate with long-term follow-up. RESULTS: A total of 3% of patients undergoing colonoscopy from January 2008 to December 2012 had same-day CTC following incomplete OC, and 72 polypectomies were performed in 34 (or 17%) of these patients. Incomplete colonoscopies were due to colon tortuosity and looping (25), severe angulations (five), colon mass (two), colon stenosis (one), bradycardia (one). Fifty-three percent of the OCs were screening for colon neoplasia, 29% diagnostic and 18% were surveillance of colon polyps. Most polyps were ≤ 5 mm, and found in the left colon. There were no reported complications or perforations associated with same-day CTCs during short- and long-term follow-up. LIMITATIONS: Limitations of our analysis included retrospective single-center design, small number of patients for the occurrence, referral to same-day CTC was not standardized, inability to establish safety of CTC for specific scenarios such as after complex polypectomies, strictures, or advanced IBD. CONCLUSIONS: Radiologists' apprehension to perform a CTC the same day as an incomplete colonoscopy following polypectomies because of perceived risk of perforation may be unfounded. More data are needed to determine the safety of same-day CTC in patients with high-risk findings during colonoscopy such as a stricture, severe IBD, and after complex polypectomies.
Project description:In everyday speech, formant transitions rarely reach the canonical frequencies of a target vowel. The perceptual system often compensates for such production undershoots, called vowel reduction (VR), by a perceptual overshoot of the final transition frequencies. The present investigation explored the perceptual parameters and existence region of VR. In a series of experiments a 100-ms steady-state vowel V(1) was followed by a formant transition toward a target vowel V(2). By manipulating both its duration and velocity, in most stimuli the transition was truncated and only seldom reached the target. After being presented with the vowel V(2) before each block of trials, listeners were asked to rate their confidence that the transition actually reached the V(2) target. Transitions along six trajectories connecting the three cardinal vowels /a/, /i/, and /u/ in both directions as well as the transition /ie/ (halfway along the trajectory /ia/) were examined in experiments in which either the duration of the transition was fixed and its velocity was varied or vice-versa. Results confirmed the existence of perceptual overshoot and showed that, at the point a transition short of reaching the vowel V(2) was just perceived as if it had reached the target, transition duration and transition velocity were inversely related. The amount of overshoot was found to be larger for larger V(1)-V(2) distances and shorter trajectory durations. The overshoot could be reliably predicted by a linear model based on three parameters--the extent of V(1)-V(2) distance, transition velocity, and transition acceleration. These findings suggest that the perceptual dynamics of speech relies on mechanisms that estimate the rate of change in the resonant characteristics of the vocal tract.
Project description:Xenopus laevis tadpoles are capable of limb regeneration following amputation, in a process which initially involves the formation of a blastema. However, Xenopus has full regenerative capacity only through premetamorphic stages. We have used the Affymetrix Xenopus laevis Genome Genechip® microarray to perform a large-scale screen of gene expression in the regeneration-complete, stage 53 (st53), and regeneration-incomplete, stage 57 (st57), hindlimbs at 1 and 5 days post-amputation. Through an exhaustive reannotation of the Genechip® and a variety of comparative bioinformatic analyses, we have identified genes that are differentially expressed between the regeneration-complete and âincomplete stages, detected the transcriptional changes associated with the regenerating blastema, and compared these results with those of other regeneration researchers. We focus particular attention on striking transcriptional activity observed in genes associated with patterning, stress response, and inflammation. Overall, this work provides the most comprehensive views yet of a regenerating limb and different transcriptional compositions of regeneration-competent and deficient tissues. Experiment Overall Design: This experiment measures gene expression in regeneration competent stage 53 and regeneration non-competent stage 57 Xenopus laevis hindlimbs, at 1 and 5 days post-amputation. Four replicates for each condition were used. Hindlimbs at either st53 or st57 were amputated unilaterally or bilaterally at the mid-zeugopodia level. One (1dPA) and 5 days (5dPA) after amputation tissues were collected 1mm proximal to the original level of amputation. Total RNA was isolated using RNaqueous micro kit (Ambion, inc.). One microgram of total RNA was amplified with the the Affymetrix 2 cycle kit and assayed per Genechip using standard Affymetrix protocols.