Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens.


ABSTRACT: PURPOSE:To predict the anterior chamber volume (ACV) after implantable collamer lens (ICL) implantation based on ICL size and parameters of anterior segment optical coherence tomography (AS-OCT). DESIGN:Retrospective study. METHODS:This study included 222 eyes of 222 patients who underwent ICL implantation at Nagoya Eye Clinic. The patients were divided into two groups: prediction group, for creating the prediction equation (148 eyes, mean age: 32.11 ± 8.04 years), and verification group, for verifying the equation (74 eyes, mean age: 33.03 ± 6.74 years). The angle opening distance (AOD), anterior chamber width (ACW), ACV, anterior chamber depth, lens vault, angle-to-angle distance, angle recess area, and trabecular iris space area were calculated using AS-OCT. A stepwise multiple regression analysis was performed. After the creation of the prediction equation, its accuracy was verified in the verification group. RESULTS:The ACV, AOD750, ACW, and ICL size were selected as explanatory variables to predict postoperative ACV. Mean predicted (114.2 ± 21.83 mm3) and actual postoperative ACVs (116.1 ± 25.41 mm3) were not significantly different (P = 0.269); absolute error was 10.59 ± 9.13 mm3. In addition, there was high correlation between actual and predictive ACV (adjusted R2 = 0.6996, p < 0.0001). Bland-Altman plot revealed that there was no addition or proportional error between predicted and actual postoperative ACV. CONCLUSION:Postoperative ACV was accurately predicted using AS-OCT parameters and ICL size. This prediction equation may be useful for making decisions regarding ICL size.

SUBMITTER: Takagi Y 

PROVIDER: S-EPMC7668562 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Prediction of anterior chamber volume after implantation of posterior chamber phakic intraocular lens.

Takagi Yuki Y   Kojima Takashi T   Nishida Tomoya T   Nakamura Tomoaki T   Ichikawa Kazuo K  

PloS one 20201116 11


<h4>Purpose</h4>To predict the anterior chamber volume (ACV) after implantable collamer lens (ICL) implantation based on ICL size and parameters of anterior segment optical coherence tomography (AS-OCT).<h4>Design</h4>Retrospective study.<h4>Methods</h4>This study included 222 eyes of 222 patients who underwent ICL implantation at Nagoya Eye Clinic. The patients were divided into two groups: prediction group, for creating the prediction equation (148 eyes, mean age: 32.11 ± 8.04 years), and veri  ...[more]

Similar Datasets

| S-EPMC8927518 | biostudies-literature
| S-EPMC9836008 | biostudies-literature
| S-EPMC5113895 | biostudies-literature
| S-EPMC7171658 | biostudies-literature
| S-EPMC5511534 | biostudies-other
| S-EPMC9115804 | biostudies-literature
| S-EPMC5757340 | biostudies-literature
| S-EPMC8832095 | biostudies-literature
| S-EPMC10019354 | biostudies-literature