Real-Time Intraoperative Pressure Monitoring to Avoid Surgically Induced Localized Brain Injury Using a Miniaturized Piezoresistive Pressure Sensor.


ABSTRACT: Neurosurgical procedures often cause damage to the brain tissue at the periphery from surgical manipulations. Especially during retraction, a large amount of pressure could be applied on the brain surface, which can damage it, leading to brain herniation, which can be fatal for patients. To resolve this issue, we have developed a pressure sensor that can be used to monitor the applied pressure during surgery for intraoperative care. This device was tested on a rodent model to create a superficial surgically induced damage profile for three different applied pressures (30, 50, and 70 mmHg) and compared to a standard intracranial pressure monitoring system. Magnetic resonance imaging has been performed after surgical procedures to detect the herniation caused by applied pressure. To evaluate the damage to brain cells and tissue rupture, histological analysis was performed using hematoxylin and eosin staining. A scoring system was developed to understand the severity of the surgically induced brain injury, which will help neurosurgeons to limit the pressure to an optimum point without causing damage.

SUBMITTER: Karmakar RS 

PROVIDER: S-EPMC7676343 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Real-Time Intraoperative Pressure Monitoring to Avoid Surgically Induced Localized Brain Injury Using a Miniaturized Piezoresistive Pressure Sensor.

Karmakar Rajat Subhra RS   Wang Jer-Chyi JC   Huang Yu-Ting YT   Lin Kun-Ju KJ   Wei Kuo-Chen KC   Hsu Yung-Hsin YH   Huang Ying-Cheng YC   Lu Yu-Jen YJ  

ACS omega 20201102 45


Neurosurgical procedures often cause damage to the brain tissue at the periphery from surgical manipulations. Especially during retraction, a large amount of pressure could be applied on the brain surface, which can damage it, leading to brain herniation, which can be fatal for patients. To resolve this issue, we have developed a pressure sensor that can be used to monitor the applied pressure during surgery for intraoperative care. This device was tested on a rodent model to create a superficia  ...[more]