In vivo 3D brain and extremity MRI at 50 mT using a permanent magnet Halbach array.


ABSTRACT: PURPOSE:To design a low-cost, portable permanent magnet-based MRI system capable of obtaining in vivo MR images within a reasonable scan time. METHODS:A discretized Halbach permanent magnet array with a clear bore diameter of 27 cm was designed for operation at 50 mT. Custom-built gradient coils, RF coil, gradient amplifiers, and RF amplifier were integrated and tested on both phantoms and in vivo. RESULTS:Phantom results showed that the gradient nonlinearity in the y-direction and z-direction was less than 5% over a 15-cm FOV and did not need correcting. For the x-direction, it was significantly greater, but could be partially corrected in postprocessing. Three-dimensional in vivo scans of the brain of a healthy volunteer using a turbo spin-echo sequence were acquired at a spatial resolution of 4 × 4 × 4 mm in a time of about 2 minutes. The T1 -weighted and T2 -weighted scans showed a good degree of tissue contrast. In addition, in vivo scans of the knee of a healthy volunteer were acquired at a spatial resolution of about 3 × 2 × 2 mm within 12 minutes to show the applicability of the system to extremity imaging. CONCLUSION:This work has shown that it is possible to construct a low-field MRI unit with hardware components costing less than 10 000 Euros, which is able to acquire human images in vivo within a reasonable data-acquisition time. The system has a high degree of portability with magnet weight of approximately 75 kg, gradient and RF amplifiers each 15 kg, gradient coils 10 kg, and spectrometer 5 kg.

SUBMITTER: O'Reilly T 

PROVIDER: S-EPMC7689769 | biostudies-literature | 2020 Jul

REPOSITORIES: biostudies-literature

altmetric image

Publications

In vivo 3D brain and extremity MRI at 50 mT using a permanent magnet Halbach array.

O'Reilly Thomas T   Teeuwisse Wouter M WM   de Gans Danny D   Koolstra Kirsten K   Webb Andrew G AG  

Magnetic resonance in medicine 20200705 1


<h4>Purpose</h4>To design a low-cost, portable permanent magnet-based MRI system capable of obtaining in vivo MR images within a reasonable scan time.<h4>Methods</h4>A discretized Halbach permanent magnet array with a clear bore diameter of 27 cm was designed for operation at 50 mT. Custom-built gradient coils, RF coil, gradient amplifiers, and RF amplifier were integrated and tested on both phantoms and in vivo.<h4>Results</h4>Phantom results showed that the gradient nonlinearity in the y-direc  ...[more]

Similar Datasets

| S-EPMC5937527 | biostudies-literature
| S-EPMC4208062 | biostudies-other
| S-EPMC8528412 | biostudies-literature
| S-EPMC8038479 | biostudies-literature
| S-EPMC4894570 | biostudies-literature
| S-EPMC7538715 | biostudies-literature
| S-EPMC5642110 | biostudies-literature
| S-EPMC8338849 | biostudies-literature
| S-EPMC6394297 | biostudies-literature
| S-EPMC3741643 | biostudies-other