Unknown

Dataset Information

0

Characterization of Legionella pneumophila Populations by Multilocus Variable Number of Tandem Repeats (MLVA) Genotyping from Drinking Water and Biofilm in Hospitals from Different Regions of the West Bank.


ABSTRACT: The West Bank can be considered a high-risk area for Legionnaires' disease (LD) due to its hot climate, intermittent water supply and roof storage of drinking water. Legionella, mostly L. pneumophila, are responsible for LD, a severe, community-acquired and nosocomial pneumonia. To date, no extensive assessment of Legionella spp and L. pneumophila using cultivation in combination with molecular approaches in the West Bank has been published. Two years of environmental surveillance of Legionella in water and biofilms in the drinking water distribution systems (DWDS) of eight hospitals was carried out; 180 L. pneumophila strains were isolated, mostly from biofilms in DWDS. Most of the isolates were identified as serogroup (Sg) 1 (60%) and 6 (30%), while a minor fraction comprised Sg 8 and 10. Multilocus Variable number of tandem repeats Analysis using 13 loci (MLVA-8(12)) was applied as a high-resolution genotyping method and compared to the standard Sequence Based Typing (SBT). The isolates were genotyped in 27 MLVA-8(12) genotypes (Gt), comprising four MLVA clonal complexes (VACC 1; 2; 5; 11). The major fraction of isolates constituted Sequence Type (ST)1 and ST461. Most of the MLVA-genotypes were highly diverse and often unique. The MLVA-genotype composition showed substantial regional variability. In general, the applied MLVA-method made it possible to reproducibly genotype the isolates, and was consistent with SBT but showed a higher resolution. The advantage of the higher resolution was most evident for the subdivision of the large strain sets of ST1 and ST461; these STs were shown to be highly pneumonia-relevant in a former study. This shows that the resolution by MLVA is advantageous for back-tracking risk sites and for the avoidance of outbreaks of L. pneumophila. Overall, our results provide important insights into the detailed population structure of L. pneumophila, allowing for better risk assessment for DWDS.

SUBMITTER: Zayed AR 

PROVIDER: S-EPMC7690423 | biostudies-literature | 2020 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Characterization of <i>Legionella pneumophila</i> Populations by Multilocus Variable Number of Tandem Repeats (MLVA) Genotyping from Drinking Water and Biofilm in Hospitals from Different Regions of the West Bank.

Zayed Ashraf R AR   Pecellin Marina M   Salah Alaa A   Alalam Hanna H   Butmeh Suha S   Steinert Michael M   Lesnik Rene R   Brettar Ingrid I   Höfle Manfred G MG   Bitar Dina M DM  

Pathogens (Basel, Switzerland) 20201022 11


The West Bank can be considered a high-risk area for Legionnaires' disease (LD) due to its hot climate, intermittent water supply and roof storage of drinking water. <i>Legionella</i>, mostly <i>L. pneumophila</i>, are responsible for LD, a severe, community-acquired and nosocomial pneumonia. To date, no extensive assessment of <i>Legionella</i> spp and <i>L. pneumophila</i> using cultivation in combination with molecular approaches in the West Bank has been published. Two years of environmental  ...[more]

Similar Datasets

| S-EPMC5930363 | biostudies-literature
| S-EPMC5377503 | biostudies-literature
| S-EPMC6468011 | biostudies-literature
| S-EPMC10675536 | biostudies-literature
| S-EPMC7761038 | biostudies-literature
| S-EPMC8066006 | biostudies-literature
| S-EPMC5430899 | biostudies-literature
| S-EPMC2937494 | biostudies-literature
| S-EPMC9869991 | biostudies-literature
| S-EPMC6585486 | biostudies-literature