Continuous and non-invasive thermography of mouse skin accurately describes core body temperature patterns, but not absolute core temperature.


ABSTRACT: Body temperature is an important physiological parameter in many studies of laboratory mice. Continuous assessment of body temperature has traditionally required surgical implantation of a telemeter, but this invasive procedure adversely impacts animal welfare. Near-infrared thermography provides a non-invasive alternative by continuously measuring the highest temperature on the outside of the body (Tskin), but the reliability of these recordings as a proxy for continuous core body temperature (Tcore) measurements has not been assessed. Here, Tcore (30 s resolution) and Tskin (1 s resolution) were continuously measured for three days in mice exposed to ad libitum and restricted feeding conditions. We subsequently developed an algorithm that optimised the reliability of a Tskin-derived estimate of Tcore. This identified the average of the maximum Tskin per minute over a 30-min interval as the optimal way to estimate Tcore. Subsequent validation analyses did however demonstrate that this Tskin-derived proxy did not provide a reliable estimate of the absolute Tcore due to the high between-animal variability in the relationship between Tskin and Tcore. Conversely, validation showed that Tskin-derived estimates of Tcore reliably describe temporal patterns in physiologically-relevant Tcore changes and provide an excellent measure to perform within-animal comparisons of relative changes in Tcore.

SUBMITTER: van der Vinne V 

PROVIDER: S-EPMC7693264 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Continuous and non-invasive thermography of mouse skin accurately describes core body temperature patterns, but not absolute core temperature.

van der Vinne Vincent V   Pothecary Carina A CA   Wilcox Sian L SL   McKillop Laura E LE   Benson Lindsay A LA   Kolpakova Jenya J   Tam Shu K E SKE   Krone Lukas B LB   Fisk Angus S AS   Wilson Tatiana S TS   Yamagata Tomoko T   Cantley James J   Vyazovskiy Vladyslav V VV   Peirson Stuart N SN  

Scientific reports 20201126 1


Body temperature is an important physiological parameter in many studies of laboratory mice. Continuous assessment of body temperature has traditionally required surgical implantation of a telemeter, but this invasive procedure adversely impacts animal welfare. Near-infrared thermography provides a non-invasive alternative by continuously measuring the highest temperature on the outside of the body (T<sub>skin</sub>), but the reliability of these recordings as a proxy for continuous core body te  ...[more]

Similar Datasets

| S-EPMC6450979 | biostudies-literature
| S-EPMC2778778 | biostudies-other
| S-EPMC7397449 | biostudies-literature
| S-EPMC3076651 | biostudies-literature
| S-EPMC5090205 | biostudies-other
| S-EPMC4887592 | biostudies-literature
| S-EPMC9239487 | biostudies-literature
| S-EPMC3660654 | biostudies-literature
| S-EPMC6415782 | biostudies-literature
| S-EPMC6601541 | biostudies-literature