Application of the Endoscopic Micro-Inspection Tool QEVO® in the Surgical Treatment of Anterior Circulation Aneurysms-A Technical Note and Case Series.


ABSTRACT: Introduction: The application of neuro-endoscopes in cerebral aneurysm surgery may help to avoid unintended aneurysm remnants and the accidental clipping of perforating arteries and aid the detection of blood collecting in the subdural spaces. Here, we present our experience with the novel endoscopic micro-inspection tool QEVO® (Carl Zeiss Meditec, Germany) in aneurysm surgery. Materials and Equipment: In all patients the surgical microscope KINEVO® (Carl Zeiss Meditec, Germany) and the Microinspection tool QEVO® were applied. Methods: The case series comprises 22 unruptured cerebral aneurysms of the anterior circulation. All aneurysms were treated surgically. All patients routinely underwent computed tomography and digital subtraction angiography within 10 days after surgery. Results: No aneurysm remnants, cerebral ischemic deficits, or subdural hematomas were detected. Discussion: In this technical note, we discuss the benefits and limitations of the QEVO® tool and illustrate the major paradigms by means of intraoperative photographs.

SUBMITTER: Schebesch KM 

PROVIDER: S-EPMC7732632 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Application of the Endoscopic Micro-Inspection Tool QEVO® in the Surgical Treatment of Anterior Circulation Aneurysms-A Technical Note and Case Series.

Schebesch Karl-Michael KM   Doenitz Christian C   Haj Amer A   Höhne Julius J   Schmidt Nils Ole NO  

Frontiers in surgery 20201124


<b>Introduction:</b> The application of neuro-endoscopes in cerebral aneurysm surgery may help to avoid unintended aneurysm remnants and the accidental clipping of perforating arteries and aid the detection of blood collecting in the subdural spaces. Here, we present our experience with the novel endoscopic micro-inspection tool QEVO® (Carl Zeiss Meditec, Germany) in aneurysm surgery. <b>Materials and Equipment:</b> In all patients the surgical microscope KINEVO® (Carl Zeiss Meditec, Germany) an  ...[more]

Similar Datasets

| S-EPMC9918798 | biostudies-literature
| S-EPMC6323537 | biostudies-literature
| S-EPMC7410369 | biostudies-literature
| S-EPMC7253549 | biostudies-literature
| S-EPMC7410374 | biostudies-literature
| S-EPMC7265348 | biostudies-literature
| S-EPMC8274159 | biostudies-literature
| S-EPMC7917011 | biostudies-literature
| S-EPMC11250084 | biostudies-literature
| S-EPMC5859685 | biostudies-literature