Unknown

Dataset Information

0

Personalized Digital-Heart Technology for Ventricular Tachycardia Ablation Targeting in Hearts With Infiltrating Adiposity.


ABSTRACT:

Background

Infiltrating adipose tissue (inFAT) is a newly recognized proarrhythmic substrate for postinfarct ventricular tachycardias (VT) identifiable on contrast-enhanced computed tomography. This study presents novel digital-heart technology that incorporates inFAT from contrast-enhanced computed tomography to noninvasively predict VT ablation targets and assesses the capability of the technology by comparing its predictions with VT ablation procedure data from patients with ischemic cardiomyopathy.

Methods

Digital-heart models reflecting patient-specific inFAT distributions were reconstructed from contrast-enhanced computed tomography. The digital-heart identification of fat-based ablation targeting (DIFAT) technology evaluated the rapid-pacing-induced VTs in each personalized inFAT-based substrate. DIFAT targets that render the inFAT substrate noninducible to VT, including VTs that arise postablation, were determined. DIFAT predictions were compared with corresponding clinical ablations to assess the capabilities of the technology.

Results

DIFAT was developed and applied retrospectively to 29 ischemic cardiomyopathy patients with contrast-enhanced computed tomography. DIFAT ablation volumes were significantly less than the estimated clinical ablation volumes (1.87±0.35 versus 7.05±0.88 cm3, P<0.0005). DIFAT targets overlapped with clinical ablations in 79% of patients, mostly in the apex (72%) and inferior/inferolateral (74%). In 3 patients, DIFAT targets colocalized with redo ablations delivered years after the index procedure.

Conclusions

DIFAT is a novel digital-heart technology for individualized VT ablation guidance designed to eliminate VT inducibility following initial ablation. DIFAT predictions colocalized well with clinical ablation locations but provided significantly smaller lesions. DIFAT also predicted VTs targeted in redo procedures years later. As DIFAT uses widely accessible computed tomography, its integration into clinical workflows may augment therapeutic precision and reduce redo procedures.

SUBMITTER: Sung E 

PROVIDER: S-EPMC7738410 | biostudies-literature |

REPOSITORIES: biostudies-literature

Similar Datasets

| S-EPMC6400313 | biostudies-literature
| S-EPMC6242273 | biostudies-literature
| S-EPMC4732176 | biostudies-other
| S-EPMC10584370 | biostudies-literature
| S-EPMC5764179 | biostudies-literature
| S-EPMC1783685 | biostudies-literature
| S-EPMC4329420 | biostudies-literature
| S-EPMC7896466 | biostudies-literature
| S-EPMC5302378 | biostudies-literature
| S-EPMC9712228 | biostudies-literature