Quantitative systematic review: Sources of inaccuracy in manually measured adult respiratory rate data.


ABSTRACT:

Aims

To identify the potential sources of inaccuracy in manually measured adult respiratory rate (RR) data and quantify their effects.

Design

Quantitative systematic review with meta-analyses where appropriate.

Data sources

Medline, CINAHL, and Cochrane Library (from database inception to 31 July 2019).

Review methods

Studies presenting data on individual sources of inaccuracy in the manual measurement of adult RR were analysed, assessed for quality, and grouped according to the source of inaccuracy investigated. Quantitative data were extracted and synthesized and meta-analyses performed where appropriate.

Results

Included studies (N = 49) identified five sources of inaccuracy. The awareness effect creates an artefactual reduction in actual RR, and observation methods involving shorter counts cause systematic underscoring. Individual RR measurements can differ substantially in either direction between observations due to inter- or intra-observer variability. Value bias, where particular RRs are over-represented (suggesting estimation), is a widespread problem. Recording omission is also widespread, with higher average rates in inpatient versus triage/admission contexts.

Conclusion

This review demonstrates that manually measured RR data are subject to several potential sources of inaccuracy.

Impact

RR is an important indicator of clinical deterioration and commonly included in track-and-trigger systems. However, the usefulness of RR data depends on the accuracy of the observations and documentation, which are subject to five potential sources of inaccuracy identified in this review. A single measurement may be affected by several factors. Hence, clinicians should interpret recorded RR data cautiously unless systems are in place to ensure its accuracy. For nurses, this includes counting rather than estimating RRs, employing 60-s counts whenever possible, ensuring patients are unaware that their RR is being measured, and documenting the resulting value. For any given site, interventions to improve measurement should take into account the local organizational and cultural context, available resources, and the specific measurement issues that need to be addressed.

SUBMITTER: Kallioinen N 

PROVIDER: S-EPMC7756810 | biostudies-literature | 2020 Oct

REPOSITORIES: biostudies-literature

altmetric image

Publications

Quantitative systematic review: Sources of inaccuracy in manually measured adult respiratory rate data.

Kallioinen Noa N   Hill Andrew A   Christofidis Melany J MJ   Horswill Mark S MS   Watson Marcus O MO  

Journal of advanced nursing 20201010 1


<h4>Aims</h4>To identify the potential sources of inaccuracy in manually measured adult respiratory rate (RR) data and quantify their effects.<h4>Design</h4>Quantitative systematic review with meta-analyses where appropriate.<h4>Data sources</h4>Medline, CINAHL, and Cochrane Library (from database inception to 31 July 2019).<h4>Review methods</h4>Studies presenting data on individual sources of inaccuracy in the manual measurement of adult RR were analysed, assessed for quality, and grouped acco  ...[more]

Similar Datasets

| S-EPMC7010823 | biostudies-literature
| S-EPMC5278896 | biostudies-other
| S-EPMC1524770 | biostudies-literature
| S-EPMC6690426 | biostudies-literature
| S-EPMC5596330 | biostudies-literature
| S-EPMC2533027 | biostudies-literature
2006-03-04 | GSE2456 | GEO
| S-EPMC6350632 | biostudies-literature
| S-EPMC4831724 | biostudies-literature
| S-EPMC2613934 | biostudies-literature