Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring.


ABSTRACT: A new approach for the sensitive, robust and rapid determination of idarubicin (IDA) in human plasma and urine samples based on liquid chromatography with fluorescence detection (LC-FL) was developed. Satisfactory chromatographic separation of the analyte after solid-phase extraction (SPE) was performed on a Discovery HS C18 analytical column using a mixture of acetonitrile and 0.1% formic acid in water as the mobile phase in isocratic mode. IDA and daunorubicin hydrochloride used as an internal standard (I.S.) were monitored at the excitation and emission wavelengths of 487 and 547 nm, respectively. The method was validated according to the FDA and ICH guidelines. The linearity was confirmed in the range of 0.1-50 ng/mL and 0.25-200 ng/mL, while the limit of detection (LOD) was 0.05 and 0.125 ng/mL in plasma and urine samples, respectively. The developed LC-FL method was successfully applied for drug determinations in human plasma and urine after oral administration of IDA at a dose of 10 mg to a patient with highly advanced alveolar rhabdomyosarcoma (RMA). Moreover, the potential exposure to IDA present in both fluids for healthcare workers and the caregivers of patients has been evaluated. The present LC-FL method can be a useful tool in pharmacokinetic and clinical investigations, in the monitoring of chemotherapy containing IDA, as well as for sensitive and reliable IDA quantitation in biological fluids.

SUBMITTER: Maliszewska O 

PROVIDER: S-EPMC7764277 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Sensitive Analysis of Idarubicin in Human Urine and Plasma by Liquid Chromatography with Fluorescence Detection: An Application in Drug Monitoring.

Maliszewska Olga O   Treder Natalia N   Olędzka IIona I   Kowalski Piotr P   Miękus Natalia N   Bączek Tomasz T   Rodzaj Wojciech W   Bień Ewa E   Krawczyk Małgorzata Anna MA   Plenis Alina A  

Molecules (Basel, Switzerland) 20201209 24


A new approach for the sensitive, robust and rapid determination of idarubicin (IDA) in human plasma and urine samples based on liquid chromatography with fluorescence detection (LC-FL) was developed. Satisfactory chromatographic separation of the analyte after solid-phase extraction (SPE) was performed on a Discovery HS C18 analytical column using a mixture of acetonitrile and 0.1% formic acid in water as the mobile phase in isocratic mode. IDA and daunorubicin hydrochloride used as an internal  ...[more]

Similar Datasets

| S-EPMC4930483 | biostudies-other
| S-EPMC7055245 | biostudies-literature
| S-EPMC6366186 | biostudies-literature
| S-EPMC3872971 | biostudies-literature
| S-EPMC3753974 | biostudies-literature
| S-EPMC8113893 | biostudies-literature
| S-EPMC5643081 | biostudies-literature
| S-EPMC3140273 | biostudies-literature
| S-EPMC8597589 | biostudies-literature
| S-EPMC7241033 | biostudies-literature