Unknown

Dataset Information

0

Adsorption of extracellular vesicles onto the tube walls during storage in solution.


ABSTRACT: Short term storage of extracellular vesicle (EV) solutions at +4°C is a common practice, but the stability of EVs during this procedure has not been fully understood yet. Using nanoparticle tracking analysis, we have shown that EVs isolated from the conditioned medium of HT-29 cells exhibit a pronounced concentration decrease when stored in PBS in ordinary polypropylene tubes within the range of (0.5-2.1) × 1010 particles/ml. EV losses reach 51±3% for 0.5 ml of EVs in Eppendorf 2 ml tube at 48 hours of storage at +4°C. Around 2/3 of the observed losses have been attributed to the adsorption of vesicles onto tube walls. This result shows that the lower part (up to at least 2 × 1010 particles/ml) of the practically relevant concentration range for purified EVs is prone to adsorption losses at +4°C. Total particle losses could be reduced to 18-21% at 48 hours by using either Eppendorf Protein LoBind tubes or ordinary tubes with the surface blocked with bovine serum albumin or EVs. Reduction of losses to 15% has been shown for isolated EVs dissolved in the supernatant after 100 000 g centrifugation as a model of conditioned medium. Also, a previously unknown feature of diffusion-controlled adsorption was revealed for EVs. In addition to the decrease in particle count, this process causes the predominant losses of smaller particles.

SUBMITTER: Evtushenko EG 

PROVIDER: S-EPMC7769454 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Adsorption of extracellular vesicles onto the tube walls during storage in solution.

Evtushenko Evgeniy G EG   Bagrov Dmitry V DV   Lazarev Vassili N VN   Livshits Mikhail A MA   Khomyakova Elena E  

PloS one 20201228 12


Short term storage of extracellular vesicle (EV) solutions at +4°C is a common practice, but the stability of EVs during this procedure has not been fully understood yet. Using nanoparticle tracking analysis, we have shown that EVs isolated from the conditioned medium of HT-29 cells exhibit a pronounced concentration decrease when stored in PBS in ordinary polypropylene tubes within the range of (0.5-2.1) × 1010 particles/ml. EV losses reach 51±3% for 0.5 ml of EVs in Eppendorf 2 ml tube at 48 h  ...[more]

Similar Datasets

| S-EPMC9105846 | biostudies-literature
| S-EPMC6094392 | biostudies-literature
| S-EPMC10787271 | biostudies-literature
| S-EPMC9206228 | biostudies-literature
| S-EPMC10938457 | biostudies-literature
| S-EPMC9298688 | biostudies-literature
| S-EPMC9352241 | biostudies-literature
| S-EPMC9491347 | biostudies-literature
| S-EPMC8770621 | biostudies-literature
| S-EPMC4643195 | biostudies-literature