Unknown

Dataset Information

0

An Electrochemical Sensor Based on Gold Nanodendrite/Surfactant Modified Electrode for Bisphenol A Detection.


ABSTRACT: In the present work, we reported the simple way to fabricate an electrochemical sensing platform to detect Bisphenol A (BPA) using galvanostatic deposition of Au on a glassy carbon electrode covered by cetyltrimethylammonium bromide (CTAB). This material (CTAB) enhances the sensitivity of electrochemical sensors with respect to the detection of BPA. The electrochemical response of the modified GCE to BPA was investigated by cyclic voltammetry and differential pulse voltammetry. The results displayed a low detection limit (22?nm) and a linear range from 0.025 to 10?µm along side with high reproducibility (RSD?=?4.9% for seven independent sensors). Importantly, the prepared sensors were selective enough against interferences with other pollutants in the same electrochemical window. Notably, the presented sensors have already proven their ability in detecting BPA in real plastic water drinking bottle samples with high accuracy (recovery range?=?96.60%-102.82%) and it is in good agreement with fluorescence measurements.

SUBMITTER: Lien NT 

PROVIDER: S-EPMC7785347 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

An Electrochemical Sensor Based on Gold Nanodendrite/Surfactant Modified Electrode for Bisphenol A Detection.

Lien Nguyen Thi NT   Quoc Hung Le L   Hoang Nguyen Tien NT   Thu Vu Thi VT   Ngoc Nga Dau Thi DT   Hai Yen Pham Thi PT   Phong Pham Hong PH   Thu Ha Vu Thi VT  

Journal of analytical methods in chemistry 20201229


In the present work, we reported the simple way to fabricate an electrochemical sensing platform to detect Bisphenol A (BPA) using galvanostatic deposition of Au on a glassy carbon electrode covered by cetyltrimethylammonium bromide (CTAB). This material (CTAB) enhances the sensitivity of electrochemical sensors with respect to the detection of BPA. The electrochemical response of the modified GCE to BPA was investigated by cyclic voltammetry and differential pulse voltammetry. The results displ  ...[more]

Similar Datasets

| S-EPMC8173557 | biostudies-literature
| S-EPMC6843716 | biostudies-literature
| S-EPMC2869627 | biostudies-literature
| S-EPMC7191228 | biostudies-literature
| S-EPMC3478800 | biostudies-other
| S-EPMC8989844 | biostudies-literature
| S-EPMC6334944 | biostudies-literature
| S-EPMC8623231 | biostudies-literature
| S-EPMC9204582 | biostudies-literature
| S-EPMC8141695 | biostudies-literature