Application of transesophageal echocardiography for localization in totally implantable venous access port implantation through subclavian approach in children.


ABSTRACT: A totally implantable venous access port (TIVAP) is important in children who need intravenous infusion for a long time. A number of studies have shown methods for locating the tip of the TIVAP catheter. To explore whether transesophageal echocardiography (TEE) can be used to accurately locate the TIVAP catheter tip through a subclavian approach and to improve the rate of correct TIVAP catheter placement and reduce complications of TIVAP placement. In 36 children who needed TIVAP implantation surgery, we used real-time TEE guidance to place the catheter tip around the crista terminalis. In all children, chest X-rays were used to figure out whether the catheter tip as localized by TEE was within the T5-T7 segment. Then, we compared the length of the catheter calculated by the height formula and the actual catheter length applied under TEE guidance. The medical records, surgical details, nursing records, and recorded complications were collected during the follow-up. The success rate of TIVAP implantation was 100% in all enrolled patients and no hemopneumothorax or pinch-off syndrome occurred. Compared with TEE, chest X-ray showed a coincidence rate of 80.56% in correctly detecting the TIVAP catheter tip locate. The height-derived catheter length (11.0 [9.6, 11.8]) cm and the TEE-derived catheter length (10.0 [9.3, 10.8]) cm were significantly different (p?

SUBMITTER: Yang S 

PROVIDER: S-EPMC7803355 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Application of transesophageal echocardiography for localization in totally implantable venous access port implantation through subclavian approach in children.

Yang Shujun S   Kong Xiangru X   Liu Lifei L   Xu Ying Y   Zhang Jun J  

Clinical cardiology 20201125 1


A totally implantable venous access port (TIVAP) is important in children who need intravenous infusion for a long time. A number of studies have shown methods for locating the tip of the TIVAP catheter. To explore whether transesophageal echocardiography (TEE) can be used to accurately locate the TIVAP catheter tip through a subclavian approach and to improve the rate of correct TIVAP catheter placement and reduce complications of TIVAP placement. In 36 children who needed TIVAP implantation su  ...[more]

Similar Datasets

| S-EPMC8106576 | biostudies-literature
| S-EPMC4141057 | biostudies-other
| S-EPMC4410572 | biostudies-other
| S-EPMC4422989 | biostudies-other
| S-EPMC8689318 | biostudies-literature
| S-EPMC6464051 | biostudies-literature
| S-EPMC120668 | biostudies-literature
| S-EPMC8632700 | biostudies-literature
| S-EPMC4396913 | biostudies-other
| S-EPMC4739717 | biostudies-other