Unknown

Dataset Information

0

Potential-induced sonoelectrochemical graphene nanosheets with vacancies as hydrogen peroxide reduction catalysts and sensors.


ABSTRACT: Defective graphene nanosheets (dGN4V) with 5-9, 5-8-5, and point defects were synthesised by a sonoelectrochemical method, where a potential of 4 V (vs. Ag/AgCl) was applied to drive the rapid intercalation of phosphate ions between the layers of the graphite foil as a working electrode. In addition to these vacancies, double vacancy defects were also created when the applied potential was increased to 8 V (dGN8V). The defect density of dGN8V (2406 ?m-2) was higher than that of dGN4V (1786 ?m-2). Additionally, dGN8V and dGN4V were applied as catalysts for the hydrogen peroxide reduction reaction (HPRR). The mass activity of dGN8V (1.31 × 10-2 mA·?g-1) was greater than that of dGN4V (1.17 × 10-2 mA·?g-1) because of its high electrochemical surface area (ECSA, 1250.89 m2·g-1) and defect density (ND, 2406 ?m-2), leading to low charge transfer resistance on the electrocatalytic interface. The ECSA and ND of dGN4V were 502.7 m2·g-1 and 1786 ?m-2, respectively. Apart from its remarkable HPRR activity, the cost-effective dGN8V catalyst also showed potential as an amperometric sensor for the determination of H2O2.

SUBMITTER: Wang TP 

PROVIDER: S-EPMC7803930 | biostudies-literature | 2020 Dec

REPOSITORIES: biostudies-literature

altmetric image

Publications

Potential-induced sonoelectrochemical graphene nanosheets with vacancies as hydrogen peroxide reduction catalysts and sensors.

Wang Tzu-Pei TP   Lee Chien-Liang CL   Kuo Chia-Hung CH   Kuo Wen-Cheng WC  

Ultrasonics sonochemistry 20201224


Defective graphene nanosheets (dGN<sub>4V</sub>) with 5-9, 5-8-5, and point defects were synthesised by a sonoelectrochemical method, where a potential of 4 V (vs. Ag/AgCl) was applied to drive the rapid intercalation of phosphate ions between the layers of the graphite foil as a working electrode. In addition to these vacancies, double vacancy defects were also created when the applied potential was increased to 8 V (dGN<sub>8V</sub>). The defect density of dGN<sub>8V</sub> (2406 μm<sup>-2</sup  ...[more]

Similar Datasets

| S-EPMC5519930 | biostudies-literature
| S-EPMC4606795 | biostudies-literature
| S-EPMC8159481 | biostudies-literature
| S-EPMC5719220 | biostudies-literature
| S-EPMC7082696 | biostudies-literature
| S-EPMC7318153 | biostudies-literature
| S-EPMC3937785 | biostudies-literature
| S-EPMC3694288 | biostudies-literature
| S-EPMC4137985 | biostudies-other