Evaluation of measures for assessing time-saving of automatic organ-at-risk segmentation in radiotherapy.


ABSTRACT:

Background and purpose

In radiotherapy, automatic organ-at-risk segmentation algorithms allow faster delineation times, but clinically relevant contour evaluation remains challenging. Commonly used measures to assess automatic contours, such as volumetric Dice Similarity Coefficient (DSC) or Hausdorff distance, have shown to be good measures for geometric similarity, but do not always correlate with clinical applicability of the contours, or time needed to adjust them. This study aimed to evaluate the correlation of new and commonly used evaluation measures with time-saving during contouring.

Materials and methods

Twenty lung cancer patients were used to compare user-adjustments after atlas-based and deep-learning contouring with manual contouring. The absolute time needed (s) of adjusting the auto-contour compared to manual contouring was recorded, from this relative time-saving (%) was calculated. New evaluation measures (surface DSC and added path length, APL) and conventional evaluation measures (volumetric DSC and Hausdorff distance) were correlated with time-recordings and time-savings, quantified with the Pearson correlation coefficient, R.

Results

The highest correlation (R = 0.87) was found between APL and absolute adaption time. Lower correlations were found for APL with relative time-saving (R = -0.38), for surface DSC with absolute adaption time (R = -0.69) and relative time-saving (R = 0.57). Volumetric DSC and Hausdorff distance also showed lower correlation coefficients for absolute adaptation time (R = -0.32 and 0.64, respectively) and relative time-saving (R = 0.44 and -0.64, respectively).

Conclusion

Surface DSC and APL are better indicators for contour adaptation time and time-saving when using auto-segmentation and provide more clinically relevant and better quantitative measures for automatically-generated contour quality, compared to commonly-used geometry-based measures.

SUBMITTER: Vaassen F 

PROVIDER: S-EPMC7807544 | biostudies-literature | 2020 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Evaluation of measures for assessing time-saving of automatic organ-at-risk segmentation in radiotherapy.

Vaassen Femke F   Hazelaar Colien C   Vaniqui Ana A   Gooding Mark M   van der Heyden Brent B   Canters Richard R   van Elmpt Wouter W  

Physics and imaging in radiation oncology 20191217


<h4>Background and purpose</h4>In radiotherapy, automatic organ-at-risk segmentation algorithms allow faster delineation times, but clinically relevant contour evaluation remains challenging. Commonly used measures to assess automatic contours, such as volumetric Dice Similarity Coefficient (DSC) or Hausdorff distance, have shown to be good measures for geometric similarity, but do not always correlate with clinical applicability of the contours, or time needed to adjust them. This study aimed t  ...[more]

Similar Datasets

| S-EPMC7807574 | biostudies-literature
| S-EPMC6076994 | biostudies-literature
| S-EPMC8202780 | biostudies-literature
| S-EPMC7212344 | biostudies-literature
| S-EPMC5690045 | biostudies-literature
| S-EPMC7807550 | biostudies-literature
| S-EPMC8283850 | biostudies-literature
| S-EPMC7921705 | biostudies-literature
| S-EPMC8397890 | biostudies-literature
| S-EPMC7673028 | biostudies-literature