Unknown

Dataset Information

0

Assessment of Systemic and Cerebral Oxygen Saturation during Diagnostic Bronchoscopy: A Prospective, Randomized Study.


ABSTRACT:

Background

Arterial hypoxemia occurs in about 2.5-69% of cases during fiberoptic bronchoscopy and may necessitate administration of supplemental oxygen. Whether routine supplementary administration is indicated for all patients is a debated issue. In this prospective randomized study, we assessed the incidence of systemic desaturation (SpO2 <90% or a >4% decrease lasting for more than 60?s) and wanted to find out whether cerebral desaturation occurs in parallel with systemic changes.

Patients and methods

92 consecutive patients scheduled for diagnostic bronchoscopy were randomly assigned to the no oxygen (O2- group), 2?l/min supplemental O2, or 4?l/min supplemental O2 groups. Primary end points were systemic and cerebral desaturation rate during the procedure. Secondary end points were to delineate the main risk factors of systemic and cerebral desaturation.

Results

In the entire cohort, systemic desaturation occurred in 18.5% of patients (n?=?17), corresponding to 5 patients (16%) in the O2 (-)group, 6 patients (19%) in the 2?l/min group, and 6 patients (20%) in 4?l/min group, respectively. In the O2 (-) group, the probability of desaturation was 41.7 times higher than that in the 2?l/min group (p=0.014 s), while there was no difference in the probabilities of desaturation between the 2?l/min and 4?l/min groups (p=0.22). Cerebral desaturation (more than 20% rSO2 decrease compared to baseline) did not occur in any patients in the three groups. Systemic desaturation developed earlier, and recovery after desaturation was longer in the O2 (-) group. Male gender, smoking, and systemic oxygen saturation at baseline and FEV1% were the most significant factors contributing to systemic desaturation during bronchoscopy.

Conclusions

Administration of supplemental oxygen does not prevent systemic desaturation during flexible bronchoscopy, but may contribute to the shortening of desaturation episodes and faster normalization of oxygen saturation. According to our results, 2?l/min supplemental oxygen should routinely be administered to patients throughout the procedure. This trial is registered with NCT04002609.

SUBMITTER: Vasko A 

PROVIDER: S-EPMC7811491 | biostudies-literature | 2020

REPOSITORIES: biostudies-literature

altmetric image

Publications

Assessment of Systemic and Cerebral Oxygen Saturation during Diagnostic Bronchoscopy: A Prospective, Randomized Study.

Vaskó Attila A   Kovács Sándor S   Fülesdi Béla B   Molnár Csilla C  

Emergency medicine international 20201209


<h4>Background</h4>Arterial hypoxemia occurs in about 2.5-69% of cases during fiberoptic bronchoscopy and may necessitate administration of supplemental oxygen. Whether routine supplementary administration is indicated for all patients is a debated issue. In this prospective randomized study, we assessed the incidence of systemic desaturation (SpO<sub>2</sub> <90% or <i>a</i> >4% decrease lasting for more than 60 s) and wanted to find out whether cerebral desaturation occurs in parallel with sys  ...[more]