Upconverting nanoparticle reporter-based highly sensitive rapid lateral flow immunoassay for hepatitis B virus surface antigen.


ABSTRACT: Detection of hepatitis B Virus surface antigen (HBsAg) is an established method for diagnosing both acute and chronic hepatitis B virus (HBV) infection. In addition to enzyme immunoassays (EIAs), rapid diagnostic tests (RDTs) are available for the detection of HBsAg in resource-poor settings. However, the available RDTs have inadequate sensitivity and therefore are not suitable for diagnosis of patients with low levels of HBsAg and for blood screening. To provide a high-sensitivity RDT, we developed a lateral flow immunoassay (LFIA) for HBsAg utilizing upconverting nanoparticle (UCNP) reporter. The UCNP-LFIA can use whole blood, serum, or plasma and the results can be read in 30 min using a reader device. When compared with a commercial conventional visually read LFIA, the developed UCNP-LFIA had a Limit of Detection (LoD) of 0.1 IU HBsAg/ml in spiked serum, whereas the LoD of the conventional LFIA was 3.2 IU HBsAg/ml. The developed UCNP-LFIA fulfills the WHO criterion for blood screening (LoD ??0.13 IU HBsAg/ml) in terms of LoD. The UCNP-LFIA and conventional LFIA were evaluated with well-characterized sample panels. The UCNP-LFIA detected 20/24 HBsAg-positive samples within the HBsAg Performance Panel and 8/10 samples within the Mixed Titer Performance Panel, whereas the conventional LFIA detected 8/24 and 4/10 samples in these panels, respectively. The performance of the assays was further evaluated with HBsAg-positive (n?=?108) and HBsAg-negative (n?=?315) patient samples. In comparison with a central laboratory test, UCNP-LFIA showed 95.4% (95% CI: 89.5-98.5%) sensitivity whereas sensitivity of the conventional LFIA was 87.7% (95%CI: 79.9-93.3%).

SUBMITTER: Martiskainen I 

PROVIDER: S-EPMC7813740 | biostudies-literature | 2021 Feb

REPOSITORIES: biostudies-literature

altmetric image

Publications

Upconverting nanoparticle reporter-based highly sensitive rapid lateral flow immunoassay for hepatitis B virus surface antigen.

Martiskainen Iida I   Talha Sheikh M SM   Vuorenpää Karoliina K   Salminen Teppo T   Juntunen Etvi E   Chattopadhyay Souvick S   Kumar Dinesh D   Vuorinen Tytti T   Pettersson Kim K   Khanna Navin N   Batra Gaurav G  

Analytical and bioanalytical chemistry 20201123 4


Detection of hepatitis B Virus surface antigen (HBsAg) is an established method for diagnosing both acute and chronic hepatitis B virus (HBV) infection. In addition to enzyme immunoassays (EIAs), rapid diagnostic tests (RDTs) are available for the detection of HBsAg in resource-poor settings. However, the available RDTs have inadequate sensitivity and therefore are not suitable for diagnosis of patients with low levels of HBsAg and for blood screening. To provide a high-sensitivity RDT, we devel  ...[more]

Similar Datasets

| S-EPMC9964500 | biostudies-literature
| S-EPMC8455528 | biostudies-literature
| S-EPMC6765353 | biostudies-literature
| S-EPMC9180083 | biostudies-literature
| S-EPMC9138499 | biostudies-literature
| S-EPMC10814772 | biostudies-literature
| S-EPMC84955 | biostudies-literature
| S-EPMC7813914 | biostudies-literature
| S-EPMC8708713 | biostudies-literature
| S-EPMC9637957 | biostudies-literature