Unknown

Dataset Information

0

Test-retest repeatability of a deep learning architecture in detecting and segmenting clinically significant prostate cancer on apparent diffusion coefficient (ADC) maps.


ABSTRACT:

Objectives

To evaluate short-term test-retest repeatability of a deep learning architecture (U-Net) in slice- and lesion-level detection and segmentation of clinically significant prostate cancer (csPCa: Gleason grade group >?1) using diffusion-weighted imaging fitted with monoexponential function, ADCm.

Methods

One hundred twelve patients with prostate cancer (PCa) underwent 2 prostate MRI examinations on the same day. PCa areas were annotated using whole mount prostatectomy sections. Two U-Net-based convolutional neural networks were trained on three different ADCm b value settings for (a) slice- and (b) lesion-level detection and (c) segmentation of csPCa. Short-term test-retest repeatability was estimated using intra-class correlation coefficient (ICC(3,1)), proportionate agreement, and dice similarity coefficient (DSC). A 3-fold cross-validation was performed on training set (N?=?78 patients) and evaluated for performance and repeatability on testing data (N?=?34 patients).

Results

For the three ADCm b value settings, repeatability of mean ADCm of csPCa lesions was ICC(3,1)?=?0.86-0.98. Two CNNs with U-Net-based architecture demonstrated ICC(3,1) in the range of 0.80-0.83, agreement of 66-72%, and DSC of 0.68-0.72 for slice- and lesion-level detection and segmentation of csPCa. Bland-Altman plots suggest that there is no systematic bias in agreement between inter-scan ground truth segmentation repeatability and segmentation repeatability of the networks.

Conclusions

For the three ADCm b value settings, two CNNs with U-Net-based architecture were repeatable for the problem of detection of csPCa at the slice-level. The network repeatability in segmenting csPCa lesions is affected by inter-scan variability and ground truth segmentation repeatability and may thus improve with better inter-scan reproducibility.

Key points

• For the three ADCm b value settings, two CNNs with U-Net-based architecture were repeatable for the problem of detection of csPCa at the slice-level. • The network repeatability in segmenting csPCa lesions is affected by inter-scan variability and ground truth segmentation repeatability and may thus improve with better inter-scan reproducibility.

SUBMITTER: Hiremath A 

PROVIDER: S-EPMC7821380 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Test-retest repeatability of a deep learning architecture in detecting and segmenting clinically significant prostate cancer on apparent diffusion coefficient (ADC) maps.

Hiremath Amogh A   Shiradkar Rakesh R   Merisaari Harri H   Prasanna Prateek P   Ettala Otto O   Taimen Pekka P   Aronen Hannu J HJ   Boström Peter J PJ   Jambor Ivan I   Madabhushi Anant A  

European radiology 20200723 1


<h4>Objectives</h4>To evaluate short-term test-retest repeatability of a deep learning architecture (U-Net) in slice- and lesion-level detection and segmentation of clinically significant prostate cancer (csPCa: Gleason grade group > 1) using diffusion-weighted imaging fitted with monoexponential function, ADC<sub>m</sub>.<h4>Methods</h4>One hundred twelve patients with prostate cancer (PCa) underwent 2 prostate MRI examinations on the same day. PCa areas were annotated using whole mount prostat  ...[more]

Similar Datasets

| S-EPMC8048287 | biostudies-literature
| S-EPMC6423042 | biostudies-literature
| S-EPMC6175053 | biostudies-literature
| S-EPMC5719052 | biostudies-literature
| S-EPMC6063352 | biostudies-literature
| S-EPMC5544576 | biostudies-literature
| S-EPMC4193754 | biostudies-literature
| S-EPMC5674133 | biostudies-literature
| S-EPMC9815750 | biostudies-literature
| S-EPMC5573303 | biostudies-literature