Dysmetabolisms Can Affect Total Antioxidant Capacity (TAC) of Human Plasma: Determination of Reference Intervals of TAC by Way of CUPRAC-BCS Method.


ABSTRACT: The total antioxidant capacity (TAC) of human plasma is an index of the redox buffer capacity of this biological fluid and could be a biomarker for those disorders affecting redox status. Distinguishing physiological from pathological conditions needs a reference. Therefore, this work aims to define the reference intervals for TAC of human plasma of apparently healthy adult individuals. TAC was measured using the CUPRAC-BCS (CUPric reducing antioxidant capacity-bathocuproinedisulfonic acid) method previously optimized and tested in a clinical laboratory. A population of 500 blood donors was selected, plus an additional 222 pathological patients carrying specific defective metabolisms, namely, hyperuricemia, hyperbilirubinemia, and type 2 diabetic mellitus. The reference intervals of TAC were calculated according to international guidelines. Due to the response of a partitioning test, the reference intervals for healthy population were separately defined for male (258) and female (151) groups. The reference intervals (µmol L-1) resulted: 727-1248 for the male subgroup and 637-1048 for the female subgroup. The absence of an age effect on TAC values was verified. The reference intervals evaluated allow a discussion on some pathological conditions overloading the plasma with redox-active waste substances.

SUBMITTER: Prenesti E 

PROVIDER: S-EPMC7824953 | biostudies-literature | 2021 Jan

REPOSITORIES: biostudies-literature

altmetric image

Publications

Dysmetabolisms Can Affect Total Antioxidant Capacity (TAC) of Human Plasma: Determination of Reference Intervals of TAC by Way of CUPRAC-BCS Method.

Prenesti Enrico E   Berto Silvia S   Gosmaro Fabio F   Bagnati Marco M   Bellomo Giorgio G  

Antioxidants (Basel, Switzerland) 20210105 1


The total antioxidant capacity (TAC) of human plasma is an index of the redox buffer capacity of this biological fluid and could be a biomarker for those disorders affecting redox status. Distinguishing physiological from pathological conditions needs a reference. Therefore, this work aims to define the reference intervals for TAC of human plasma of apparently healthy adult individuals. TAC was measured using the CUPRAC-BCS (CUPric reducing antioxidant capacity-bathocuproinedisulfonic acid) meth  ...[more]

Similar Datasets

| S-EPMC6582112 | biostudies-literature
| S-EPMC4685244 | biostudies-other
| S-EPMC6291249 | biostudies-literature
| S-EPMC8145038 | biostudies-literature
| S-EPMC9119462 | biostudies-literature
| S-EPMC10487251 | biostudies-literature
| S-EPMC10536404 | biostudies-literature
| S-EPMC8046200 | biostudies-literature
| S-EPMC6784422 | biostudies-literature
| S-EPMC9313937 | biostudies-literature