Unknown

Dataset Information

0

Sutureless Intrascleral Posterior Chamber Intraocular Lens Fixation: Analysis of Clinical Outcomes and Postoperative Complications.


ABSTRACT:

Purpose

To report a technique for performing sutureless intrascleral fixation of a posterior chamber intraocular lens (PC-IOL) and analyzing the clinical outcomes and postoperative complications. Study Design. 68 eyes of 66 patients who received the technique were studied retrospectively.

Methods

The best-corrected visual acuity (BCVA), intraocular pressure (IOP), anterior chamber depth (ACD), IOL tilt and decentration, corneal topography (K1 and K2), and postoperative complications were determined at 3 months.

Results

The mean preoperative BCVA was 1.63 ± 1.24 logMAR units, and the mean postoperative BCVA was 0.74 ± 0.59 logMAR units at 3 months (P < 0.05). The mean preoperative IOP was 21.9 ± 12.6 mmHg, and the mean postoperative IOP was 16.9 ± 4.5 mmHg at 3 months (P = 0.001). The mean preoperative corneal topography (K1 and K2) was K1 = 42.14 ± 1.91 and K2 = 43.54 ± 1.51; the mean postoperative corneal topography (K1 and K2) was K1 = 43.03 ± 2.18 and K2 = 43.40 ± 1.71 at 3 months (P = 0.678 and 0.468, respectively). The mean preoperative spherical equivalent was +11.00 ± 13.19 diopters (D), and the mean postoperative spherical equivalent was +0.06 ± 0.86 D (P < 0.005). The mean IOL tilt was 2.4 ± 1.7°, and the mean decentration was 0.35 ± 0.21 mm. The mean ACD was 4.31 ± 0.29 mm.

Conclusions

The 27-gauge sutureless intrascleral PC-IOL implantation technique minimizes intraoperative injury, simplifies procedure, and provides good PC-IOL fixation with few postoperative complications.

SUBMITTER: Liu J 

PROVIDER: S-EPMC7826223 | biostudies-literature | 2021

REPOSITORIES: biostudies-literature

altmetric image

Publications

Sutureless Intrascleral Posterior Chamber Intraocular Lens Fixation: Analysis of Clinical Outcomes and Postoperative Complications.

Liu Jiannan J   Fan Wenxue W   Lu Xinyu X   Peng Shaomin S  

Journal of ophthalmology 20210116


<h4>Purpose</h4>To report a technique for performing sutureless intrascleral fixation of a posterior chamber intraocular lens (PC-IOL) and analyzing the clinical outcomes and postoperative complications. <i>Study Design</i>. 68 eyes of 66 patients who received the technique were studied retrospectively.<h4>Methods</h4>The best-corrected visual acuity (BCVA), intraocular pressure (IOP), anterior chamber depth (ACD), IOL tilt and decentration, corneal topography (<i>K</i>1 and <i>K</i>2), and post  ...[more]

Similar Datasets

| S-EPMC3376277 | biostudies-literature
| S-EPMC8544105 | biostudies-literature
| S-EPMC6136496 | biostudies-literature
| S-EPMC5742981 | biostudies-literature
| S-EPMC10229913 | biostudies-literature
| S-EPMC11346030 | biostudies-literature
| S-EPMC11624642 | biostudies-literature
| S-EPMC10003268 | biostudies-literature
| S-EPMC5742965 | biostudies-literature
| S-EPMC6836613 | biostudies-literature