ABSTRACT: Importance
Frequent right ventricular (RV) pacing can cause and exacerbate heart failure. Cardiac resynchronization therapy (CRT) has been shown to be associated with improved outcomes among patients with reduced left ventricular ejection fraction who need frequent RV pacing, but the patterns of use of CRT vs dual chamber (DC) devices and the associated outcomes among these patients in clinical practice is not known.Objective
To assess outcomes, variability in use of device type, and trends in use of device type over time among patients undergoing implantable cardioverter defibrillator (ICD) implantation who were likely to require frequent RV pacing but who did not have a class I indication for CRT.Design, setting, and participants
This retrospective cohort study used the National Cardiovascular Data Registry (NCDR) ICD Registry. A total of 3100 Medicare beneficiaries undergoing first-time implantation of CRT defibrillator (CRT-D) or DC-ICD from 2010 to 2016 who had a class I or II guideline ventricular bradycardia pacing indication but not a class I indication for CRT were included. Data were analyzed from August 2018 to October 2019.Exposures
Implantation of a CRT-D or DC-ICD.Main outcomes and measures
All-cause mortality, heart failure hospitalization, and complications were ascertained from Medicare claims data. Multivariable Cox proportional hazards models and Fine-Gray models were used to evaluate 1-year mortality and heart failure hospitalization, respectively. Multivariable logistic regression was used to evaluate 30-day and 90-day complications. All models accounted for clustering. The median odds ratio (MOR) was used to assess variability and represents the odds that a randomly selected patient receiving CRT-D at a hospital with high implant rates would receive CRT-D if they had been treated at a hospital with low CRT-D implant rates.Results
A total of 3100 individuals were included. The mean (SD) age was 76.3 (6.4) years, and 2500 (80.6%) were men. The 1698 patients (54.7%) receiving CRT-D were more likely than those receiving DC-ICD to have third-degree atrioventricular block (828 [48.8%] vs 432 [30.8%]; P?Conclusions and relevanceIn this cohort study of older patients in contemporary practice undergoing ICD implantation with a bradycardia pacing indication but without a class I indication for CRT, CRT-D was associated with better outcomes compared with DC devices. Variability in use of device type was observed, and the rate of CRT implantation increased over time.
SUBMITTER: Borne RT
PROVIDER: S-EPMC7838925 | biostudies-literature | 2021 Jan
REPOSITORIES: biostudies-literature
JAMA network open 20210104 1
<h4>Importance</h4>Frequent right ventricular (RV) pacing can cause and exacerbate heart failure. Cardiac resynchronization therapy (CRT) has been shown to be associated with improved outcomes among patients with reduced left ventricular ejection fraction who need frequent RV pacing, but the patterns of use of CRT vs dual chamber (DC) devices and the associated outcomes among these patients in clinical practice is not known.<h4>Objective</h4>To assess outcomes, variability in use of device type, ...[more]