Unknown

Dataset Information

0

Wearable cardioverter-defibrillator in patients with a transient risk of Sudden cardiac death: the WEARIT-France cohort study.


ABSTRACT:

Aims?

We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability.

Methods and results?

Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education session through a standardized programme across France at the time of initiation of WCD therapy and were systematically enrolled in the LifeVest Network remote services. Overall, 1157 patients were included (mean age 60?±?12?years, 16% women; 46% prospectively): 82.1% with ischaemic cardiomyopathy, 10.3% after implantable cardioverter-defibrillator explant, and 7.6% before heart transplantation. Median WCD usage period was 62 (37-97) days. Median daily wear time of WCD was 23.4 (22.2-23.8) h. In multivariate analysis, younger age was associated with lower compliance [adjusted odds ratio (OR) 0.97, 95% confidence interval (CI) 0.95-0.99, P?ConclusionOur real-life findings reinforce previous studies on the efficacy and safety of the WCD in the setting of transient high-risk group in selected patients. Moreover, they emphasize the fact that when prescribed appropriately, in concert with adequate patient education and dedicated follow-up using specific remote monitoring system, compliance with WCD is high and the device well-tolerated by the patient.

SUBMITTER: Garcia R 

PROVIDER: S-EPMC7842091 | biostudies-literature | 2020 Nov

REPOSITORIES: biostudies-literature

altmetric image

Publications

Wearable cardioverter-defibrillator in patients with a transient risk of sudden cardiac death: the WEARIT-France cohort study.

Garcia Rodrigue R   Combes Nicolas N   Defaye Pascal P   Narayanan Kumar K   Guedon-Moreau Laurence L   Boveda Serge S   Blangy Hugues H   Bouet Jérôme J   Briand Florent F   Chevalier Philippe P   Cottin Yves Y   Da Costa Antoine A   Degand Bruno B   Deharo Jean-Claude JC   Eschalier Romain R   Extramiana Fabrice F   Goralski Marc M   Guy-Moyat Benoit B   Guyomar Yves Y   Hermida Jean-Sylvain JS   Jourda François F   Lellouche Nicolas N   Mahfoud Mohanad M   Manenti Vladimir V   Mansourati Jacques J   Martin Angéline A   Pasquié Jean-Luc JL   Ritter Philippe P   Rollin Anne A   Tibi Thierry T   Yalioua Arab A   Gras Daniel D   Sadoul Nicolas N   Piot Olivier O   Leclercq Christophe C   Marijon Eloi E  

Europace : European pacing, arrhythmias, and cardiac electrophysiology : journal of the working groups on cardiac pacing, arrhythmias, and cardiac cellular electrophysiology of the European Society of Cardiology 20210101 1


<h4>Aims</h4>We aimed to provide contemporary real-world data on wearable cardioverter-defibrillator (WCD) use, not only in terms of effectiveness and safety but also compliance and acceptability.<h4>Methods and results</h4>Across 88 French centres, the WEARIT-France study enrolled retrospectively patients who used the WCD between May 2014 and December 2016, and prospectively all patients equipped for WCD therapy between January 2017 and March 2018. All patients received systematic education ses  ...[more]

Similar Datasets

| S-EPMC5864098 | biostudies-literature
| S-EPMC7252786 | biostudies-literature
| S-EPMC6276371 | biostudies-literature
| S-EPMC5491470 | biostudies-other
| S-EPMC5089470 | biostudies-literature
| S-EPMC8747379 | biostudies-literature